Energy Performance Analysis and Study of an Office Building in an Extremely Hot and Cold Region

Author:

Liu Yunbo1,Wang Wanjiang1,Huang Yumeng1,Song Junkang2,Zhou Zhenan3

Affiliation:

1. College of Architectural and Civil Engineering, Xinjiang University, Urumqi 830017, China

2. College of Architectural and Environment, Sichuan University, Chengdu 610000, China

3. School of Control and Computer Engineering, North China Electric Power University, Baoding 071000, China

Abstract

China is committed to reaching peak carbon by 2030 and carbon neutrality by 2060. The goals of reducing energy consumption and building a “beautiful China” are being urgently pursued in China. The building studied in this paper is located in the city of Turpan, where the problem of excessive energy use among buildings is significant due to the region’s hot summers and cold winters. Additionally, the fact that the office building studied in this paper has an east–west orientation is significant: the building’s main façade is oriented to the west, comprising a large area of single-layer glass curtain wall. Based on this, this paper proposes optimization strategies from two perspectives of renovation and new construction. Four design options are proposed at the retrofit level: glazed circular curtain wall; glazed enclosed curtain wall; west-facing double-glazed curtain wall circulation combined with south-facing light from the east; recycling of windows on the inside of the exterior glass curtain wall. These suggestions focus on retrofitting the glass curtain wall on the west elevation of the building. Two design options are proposed at the new-build level: west-facing south-oriented light and west-facing north-oriented light. These suggestions were primarily built around the idea of changing the orientation of the windows on the west elevation. The results show that the optimal solution is to implement the west-facing double-glazed curtain wall circulation combined with south-facing light from the east. This program shows a 64.14% reduction in heating energy consumption, a 77.12% reduction in cooling energy consumption, and a 69.67% reduction in total energy consumption. The above research has improved the deficiencies in the performance-based energy efficiency retrofit of office buildings in the region and provided new ideas and suggestions for policymakers and designers to build energy-efficiency retrofits in the early stages.

Publisher

MDPI AG

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3