Affiliation:
1. Department of Electrical Engineering, American University of Sharjah, Sharjah P.O. Box 26666, United Arab Emirates
Abstract
Dynamic wireless charging (DWC) systems enable electric vehicles (EVs) to receive energy on the move, without stopping at charging stations. Nonetheless, the energy efficiency of DWC systems is affected by the inherent misalignments of the mobile EVs, causing fluctuations in the amount of energy transmitted to the EVs. In this work, a multi-coil secondary-side inductive link (IL) design is proposed with independent double-D (DD) and quadrature coils to reduce the effect of coupling fluctuations on the power received during misalignments. Dual-sided inductor–capacitor–capacitor (LCC) compensation networks are utilized with power and current control circuits to provide a load-independent, constant current output at different misalignment conditions. The LCC compensation components are tuned to maximize the power transferred at the minimum acceptable coupling point, kmin. This compensates for the leaked energy during misalignments and minimizes variations in the operating frequency during zero-phase angle (ZPA) operation. Simulations reveal an almost constant output power for different lateral misalignment (LTMA) values up to ±200 mm for a 25 kW system, with a power transfer efficiency of 90%. A close correlation between simulation and experimental results is observed.
Funder
American University of Sharjah
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献