Dosimetric Evaluation of the Inter-Fraction Motion of Organs at Risk in SBRT for Nodal Oligometastatic Prostate Cancer

Author:

La Fauci FrancescoORCID,Augugliaro Matteo,Mazzola Giovanni CarloORCID,Comi Stefania,Pepa Matteo,Zaffaroni MattiaORCID,Vincini Maria GiuliaORCID,Corrao GiuliaORCID,Mistretta Francesco AlessandroORCID,Luzzago Stefano,Fodor Cristiana,Musi Gennaro,Gallo SalvatoreORCID,Petralia Giuseppe,De Cobelli Ottavio,Orecchia Roberto,Cattani Federica,Marvaso GiuliaORCID,Jereczek-Fossa Barbara Alicja

Abstract

In this paper, we aim to evaluate the entity of inter-fraction organ motion and deformation in stereotactic body radiotherapy (SBRT) treatments for nodal oligometastatic prostate cancer (PCa). Thirty-three patients with lymph nodes showing oligometastatic PCa treated with SBRT were included. Organs at risk (OARs) were delineated using both simulation computer tomography (s-CT) and daily cone beam CTs (CBCTs) using the Raystation planning system. For each OAR, the union volume (UV) between all the CBCTs and s-CT was computed. An expanded volume (EV) of the s-CT OARs was applied using six different margins (3, 5, 8, 10, 15, and 20 mm). A percentage volume (V%) was computed to assess the intersection between each EV and UV. The OAR deformation and motion were further evaluated using the dice similarity coefficient (DSC) and mean distance to agreement (Mean_DA). The percentage maximum dose variations for all the OARs were estimated. A recalculation with higher dose prescriptions was performed by prescribing 36 Gy/3 fx, as well as 45 Gy/3 fx. The cauda showed the highest matching (DSC = 0.72; Mean_DA = 0.14 cm), and the colon showed the lowest one (DSC = 0.37; Mean_DA = 0.44 cm). The minimum margin, which ensured a V% > 95%, was 3 mm (97.5%) for the cauda and 15 mm (96.6%) for the colon. All the OARs reached the compliance of the constraints in each session. Regarding 36 Gy-plans, the ileum punctual compliance Dmax failed in 58.8% of patients, and it failed in 70.6% of the patients for the ileum, 7.14% for the colon, and 12.5% for the bladder in the case of 45 Gy-plans. This study is an ancillary study of the RADIOSA clinical trial (AIRC IG-22159) and can be used as a benchmark for dose escalation.

Funder

Associazione Italiana per la Ricerca sul Cancro

Italian Ministry of Health

Accuray Incorporated, Medical Equipment Manufacturing, Sunnyvale, CA, USA

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3