Lower Patient Height and Weight Are Predisposing Factors for Complex Radial Arterial Catheterization

Author:

Huber Kristine1,Menzenbach Jan1,Velten Markus1ORCID,Kim Se-Chan2,Hilbert Tobias1ORCID

Affiliation:

1. Department of Anesthesiology and Intensive Care Medicine, University Hospital Bonn, Venusberg-Campus 1, 53127 Bonn, Germany

2. Department of Anesthesiology, Perioperative Care and Pain Medicine, RKH Hospital gGmbH, Kurt-Lindemann-Weg 10, 71706 Markgröningen, Germany

Abstract

Background: Radial artery (RA) catheterization for invasive blood pressure monitoring is often performed via palpation, and an ultrasound is used secondarily only in case of multiple unsuccessful attempts. Although more elaborate, it has been shown that primary ultrasound-guided catheterization may be advantageous compared with palpation. The aim of this study was to identify factors associated with difficult RA catheterization. Methods: Left RA ultrasound assessments were performed in patients with indicated invasive blood pressure monitoring the day before surgery. RA catheterization was performed by personnel blinded to the ultrasound results. Based on the number of attempts needed for successful catheter placement, the cohort was divided into uncomplicated (group 1) and difficult (more than one attempt, group 2) catheterization cases. Cases subjected to primary ultrasound were excluded from the analysis. Results: Body weight, height and surface area (BSA) of patients in group 2 (n = 16) were significantly lower than those of patients in group 1 (n = 25), and internal RA diameters were significantly smaller in group 2 patients. In the whole cohort, BSA was significantly associated with distal and proximal internal RA diameters. In contrast, no differences were observed in the skin-to-artery distance, the longitudinal axis deviation (kinking) or blood flow velocity. Median time to successful catheterization was 77 (47–179) s. Prolonged time needed for cannulation was significantly associated with lower body weight, BMI and BSA, and with reduced distal and proximal internal RA diameter. Conclusions: RA catheterization performed through pulse palpation may be difficult, especially in adult patients with lower body weight and height, due to reduced arterial diameters. Initial use of ultrasound in these patients may reduce first-attempt failure, preventing procedural delays and patient discomfort.

Publisher

MDPI AG

Subject

General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3