Calibration Experiment and Temperature Compensation Method for the Thermal Output of Electrical Resistance Strain Gauges in Health Monitoring of Structures
Author:
Jin Zhihao1, Li Yuan12ORCID, Fan Dongjue1, Tu Caitao1, Wang Xuchen1, Dang Shiyong1
Affiliation:
1. Department of Civil Engineering, University of Science and Technology Beijing, Beijing 100083, China 2. Shunde Innovation School, University of Science and Technology Beijing, Foshan 528399, China
Abstract
Electrical resistance strain gauges are widely used in asymmetric structures for measurement and monitoring, but their thermal output in changing temperature environments has a significant impact on the measurement results. Since thermal output is related to the coefficient of thermal expansion of the strain gauge’s sensitive grating material and the measured object, the temperature self-compensation technique of strain gauges fails to eliminate the additional strain caused by temperature because it cannot match the coefficient of thermal expansion of various measured objects. To address this problem, in this study, the principle of the thermal output of electrical resistance strain gauges was analyzed, a calibration experiment for thermal output in the case of a mismatch between the coefficient of linear expansion of the measured object and the strain gauge grating material was conducted, and the mechanism for temperature influence on thermal output was revealed. A method was proposed to obtain the thermal output curves for different materials by using thermostats with dual temperatures to conduct temperature calibration experiments. A linear regression method was used to obtain a linear formula for the thermal output corresponding to each temperature. The thermal output conversion relationship was derived for materials with different coefficients of linear expansion. An in situ temperature compensation technique for electrical resistance strain gauges that separates the measured strain into thermal and mechanical strains was proposed. The results showed that the thermal output curve for the measured object can be calibrated in advance and then deducted from the measured strain, thus reducing the influence of temperature-induced additional strain on the mechanical strain. In addition, a new method was provided for the calculation of the thermal output among materials with similar coefficients of linear expansion, providing a reference for the health monitoring of asymmetric structures.
Funder
Foshan Science and Technology Innovation Special Fund Funding Project National Key Research and Development Program of China
Subject
Physics and Astronomy (miscellaneous),General Mathematics,Chemistry (miscellaneous),Computer Science (miscellaneous)
Reference32 articles.
1. Strain gauge based microsensor for stress analysis in building structures;Tegtmeier;Measurement,2008 2. Yang, Y. (2022). Special Issue Editorial “Symmetry in Structural Health Monitoring”. Symmetry, 14. 3. Lei, J., Kong, Q., Wang, X., and Zhan, K. (2022). Strain Monitoring-Based Fatigue Assessment and Remaining Life Prediction of Stiff Hangers in Highway Arch Bridge. Symmetry, 14. 4. Ding, M., Shen, Y., Wei, Y., Luo, B., Wang, L., and Zhang, N. (2021). Preliminary Design and Experimental Study of a Steel-Batten Ribbed Cable Dome. Symmetry, 13. 5. Shi, G., Liu, Z., Meng, X., and Wang, Z. (2023). Intelligent Health Monitoring of Cable Network Structures Based on Fusion of Twin Simulation and Sensory Data. Symmetry, 15.
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|