Health Technology Assessment of Cardiopulmonary Bypass Circuit with and without Phosphorylcholine Coating: A Retrospective Study on Safety and Efficiency in Cardiac Surgery

Author:

Condello Ignazio1ORCID,Nasso Giuseppe1ORCID,Scrivo Salvatore1,Fiore Flavio1,Speziale Giuseppe1

Affiliation:

1. Department of Cardiac Surgery, Anthea Hospital, GVM Care & Research, 70124 Bari, Italy

Abstract

Background: Phosphorylcholine has emerged as a potential adjunctive agent in cardiopulmonary bypass (CPB) circuits. Phosphorylcholine serves as a coating for the CPB circuit, potentially enhancing biocompatibility and reducing thrombotic events. However, its impact on specific patient populations and procedural outcomes remains underexplored. Materials and Methods: In this retrospective study, we analyzed data from 60 patients who underwent cardiac surgery with CPB, comprising 20 cases each of coronary artery bypass grafting (CABG), mitral valve repair, and aortic valve replacement. The patient cohort was divided into two groups—30 patients whose CPB circuits were coated with phosphorylcholine (phosphorylcholine-coated group) and 30 patients who did not receive phosphorylcholine supplementation or circuit coating. Both groups underwent surgery with identical CPB circuit designs. We assessed the absence of adverse events, safety, and efficacy parameters, including blood loss, clotting, and the structural integrity of the CPB circuit. Additionally, we measured changes in mean albumin levels (g/dL), mean platelet counts (×109/L), and antithrombin III (ATIII) levels before and after CPB. Results: The retrospective analysis revealed an absence of adverse events in both groups. In the phosphorylcholine-coated group compared to the non-phosphorylcholine-coated group, there was a notable difference in the delta change in mean albumin levels (0.87 ± 0.1 vs. 1.65 ± 0.2 g/dL, p-value 0.021), mean platelet counts (42.251 ± 0.121 vs. 54.21 ± 0.194 × 109/L, p-value 0.049), and ATIII levels (16.85 ± 0.2 vs. 31.21 ± 0.3 p-value 0.017). There was a notable reduction in the perioperative consumption of human complex units after CPB (3 vs. 12, p-value 0.019). Conclusions: Both groups, phosphorylcholine and non-phosphorylcholine, demonstrated the absence of adverse events and that the systems are safe for iatrogenic complication. Our findings suggest that the use of phosphorylcholine coating on the CPB circuit, in the absence of supplementary phosphorylcholine, in cardiac surgery is associated with favorable changes in mean albumin levels, mean platelet counts, and ATIII levels. Further research is warranted to elucidate the full extent of phosphorylcholine’s impact on patient outcomes and CPB circuit performance.

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3