The Removal of As(III) Using a Natural Laterite Fixed-Bed Column Intercalated with Activated Carbon: Solving the Clogging Problem to Achieve Better Performance

Author:

Ouedraogo Régie Dimanche1,Bakouan Corneille123ORCID,Sakira Abdoul Karim45,Sorgho Brahima1,Guel Boubié1ORCID,Somé Touridomon Issa4,Hantson Anne-Lise3,Ziemons Eric6ORCID,Mertens Dominique5,Hubert Philippe6,Kauffmann Jean-Michel5

Affiliation:

1. Laboratoire de Chimie Moléculaire et des Matériaux (LC2M)/Equipe Chimie Physique et d’Electrochimie, U.F.R–SEA, Université Joseph KI-ZERBO, 03 BP 7021, Ouagadougou 03, Burkina Faso

2. Laboratoire de Recherche et Développement (LRD), Unité de Formation en Sciences et Technologies (UFR-ST), Université de Ouahigouya, 01 BP 346, Ouahigouya 01, Burkina Faso

3. Département Génie des Procédés Chimiques et Biochimiques, Faculté Polytechnique, UMONS, Place du Parc 21, 7000 Mons, Belgium

4. Laboratoire de Chimie Analytique et de Toxicologie, Laboratoire de Toxicologie, Environnement et Santé, U.F.R–SDS, Université Joseph KI-ZERBO, 03 BP 7021, Ouagadougou 03, Burkina Faso

5. Laboratoire de Chimie Analytique Instrumentale et Bioélectrochimie, Université Libre de Bruxelles (ULB), Campus de la Plaine, CP 205/6, 1050 Bruxelles, Belgium

6. Laboratoire de Chimie Analytique Pharmaceutique, VibraSante Hub, Département de Pharmacie, Université de Liège (ULiège), Avenue Hippocrate 15, B36, 4000 Liège, Belgium

Abstract

Natural laterite fixed-bed columns intercalated with two types of layers (inert materials, such as fine sand and gravel, and adsorbent materials, such as activated carbon prepared from Balanites aegyptiaca (BA-AC)) were used for As(III) removal from an aqueous solution. Investigations were carried out to solve the problem of column clogging, which appears during the percolation of water through a natural laterite fixed-bed column. Experimental tests were conducted to evaluate the hydraulic conductivities of several fixed-bed column configurations and the effects of various parameters, such as the grain size, bed height, and initial As(III) concentration. The permeability data show that, among the different types of fixed-bed columns investigated, the one filled with repeating layers of laterite and activated carbon is more suitable for As(III) adsorption, in terms of performance and cost, than the others (i.e., non-intercalated laterite; non-intercalated activated carbon, repeating layers of laterite and fine sand; and repeating layers of laterite and gravel). A study was carried out to determine the most efficient column using breakthrough curves. The breakthrough increased from 15 to 85 h with an increase in the bed height from 20 to 40 cm and decreased from 247 to 32 h with an increase in the initial As(III) concentration from 0.5 to 2 mg/L. The Bohart–Adams model results show that increasing the bed height induced a decrease in the kAB and N0 values. The critical bed depths determined using the bed depth service time (BDST) model for As(III) removal were 15.23 and 7.98 cm for 1 and 20% breakthroughs, respectively. The results show that the new low-cost adsorptive porous system based on laterite layers with alternating BA-AC layers can be used for the treatment of arsenic-contaminated water.

Funder

ARES-CCD (Belgium), the Synergy 2018 project

International Science Program

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3