Development of Micro-Column Preconcentration Method Using a Restricted-Access Poly(protoporphyrin-co-vinyl pyridine) Adsorbent for Copper Determination in Water and Milk Samples by FIA-FAAS

Author:

Cajamarca Suquila Fabio12ORCID,Bertoldo Letícia2,Lins Eduardo2,Tarley César234

Affiliation:

1. Department of Biology, National Pedagogic University (UPN), Cll 72 # 11-86, Bogotá 110231, Colombia

2. Department of Chemistry, State University of Londrina (UEL), Rodovia Celso Garcia Cid, PR 445, km 380, CEP, Londrina 86050-482, Brazil

3. National Institute of Science and Technology of Bioanalytics (INCTBio), Campinas 13083-970, Brazil

4. Department of Analytical Chemistry, Institute of Chemistry–Unicamp, P.O. Box 6154, Campinas 13084-974, Brazil

Abstract

For years, researchers have focused on the determination of metal ions at trace levels in environmental and food samples using analytical methods that employ techniques with low cost acquisition and maintenance and without microwave-assisted acid digestion procedures or aggressive reagents. Therefore, the present study deals with the synthesis and application of a novel, restricted-access poly(protoporphyrin-co-vinyl pyridine) adsorbent to preconcentrate copper in water samples and bovine milk that have only been subjected to pH adjusting (pH 6.0) and filtration using posterior on-line determination by FAAS. Regarding macromolecules, the restricted-access property of the adsorbent was achieved using the hydrophilic compound 2-hydroxyethyl methacrylate (HEMA). This method is based on the preconcentration of Cu2+ ions using a flow-injection system which is buffered with 0.05 mol L−1 of Britton–Robinson (BR) at a pH of 6.0 and has a flow rate of 14.0 mL min−1 through a mini-column packed with 50.0 mg of adsorbent. The elution was carried out using 0.40 mol L−1 of HCl toward the FAAS detector. The developed method provided a preconcentration factor of 44.7-fold, low limits of detection (LOD) (0.90 µg L−1) and quantification (LOQ) (2.90 µg L−1), tolerance to interfering ions (95.0 and 103.0%), and intra-day and inter-day precision assessed as the RSD (percentage of relative standard deviation), which ranged from 3.08 to 4.80%. The restricted-access poly(protoporphyrin-co-vinyl pyridine) adsorbent demonstrated outstanding features to exclude macromolecules, bovine serum albumin (BSA), and humic acid (HA) from an aqueous medium. Lake water and bovine milk samples were analyzed by the proposed preconcentration method with minimal sample pretreatment (which was based mainly on pH adjusting and filtration using an analytical curve with external calibration), yielding recovery values from addition and recovery tests ranging from 91.7 to 101.9%. The developed method shows great advantages over previously published methods, avoiding the time-consuming use of concentrated acids in a microwave-assisted acid digestion procedure.

Funder

Coordenação de Aperfeiçoamento de Nível Superior

Conselho Nacional de Desenvolvimento Científico e Tecnológico

Instituto Nacional de Ciência e Tecnologia de Bioanalítica

Publisher

MDPI AG

Subject

Filtration and Separation,Analytical Chemistry

Reference61 articles.

1. Copper storage diseases: Menkes, Wilsons, and cancer;Daniel;Front. Biosci.,2004

2. Biological role of copper as an essential trace element in the human organism;Čes. Slov. Farm.,2018

3. Royer, A., and Sharman, T. (2022). StatPearls, StatPearls Publishing.

4. (2022, December 12). ANVISA-Agência Nacional de Vigilância Sanitária-RESOLUÇÃO-RDC Nº 269, de 22 de setembro de 2005, Available online: https://bvsms.saude.gov.br/bvs/saudelegis/anvisa/2005/rdc0269_22_09_2005.html.

5. (2023, January 18). Evaluations of the Joint FAO/WHO Expert Committee on Food Additives (JECFA)–Copper. Available online: https://apps.who.int/food-additives-contaminants-jecfa-database/Home/Chemical/2824.

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3