Multivariate Optimization of Chromatographic Conditions for Rapid Simultaneous Quantification of Antidiarrheal Drugs in Formulation Using Surface Response Methodology

Author:

Attimarad MaheshORCID,Venugopala Katharigatta NarayanaswamyORCID,Chohan Muhammad S.,Shinu PottathilORCID,David Marysheela,Molina Effren II Plaza,Nair Anroop BalachandranORCID,Sreeharsha NagarajaORCID,Altaysan Abdulrahman Ibrahim,Balgoname Abdulmalek AhmedORCID

Abstract

A combination of antibiotics and antiprotozoal and antisecretory medicines has been prescribed for the treatment of diarrhea. A rapid, reproducible liquid chromatographic procedure was established for the concurrent analysis of metronidazole (MET), ofloxacin (OFL), and racecadotril (RAC) in suspension. The Box–Behnken design, a full factorial multivariate optimization technique, was utilized to optimize chromatographic parameters with fewer runs. The separation of MET, OFL, and RAC was accomplished within 3.2 min, using a Zorbax C18 high-performance liquid chromatography column with a simple mobile phase comprising acetonitrile (55 vol.%): methanol (10 vol.%):20 mM phosphate buffer (35 vol.%, pH 6, regulated with ortho-phosphoric acid). The mobile phase was pumped in the isocratic mode at a rate of 1.4 mL/min at ambient temperature. Analytes were monitored by adjusting the wavelength at 295 nm for MET and OFL and 231 nm for RAC. Validation of the proposed HPLC method exhibited linearity in the concentration of 20–250 µg/mL, 10–150 µg/mL, and 5–80 µg/mL for MET, OFL, and RAC respectively, along with an excellent regression coefficient (r2 > 0.999). The accuracy and precision of the chromatographic procedure were also evidenced by the low percent relative error and relative standard deviation. A Pareto chart developed by the two-factor interaction (2FI) study confirmed that the method was robust, as the slight variation in a single factor had no significant influence on the assay outcomes. Lastly, the developed HPLC process was utilized for the concurrent quantification of MET, OFL, and RAC in liquid oral preparation. Furthermore, when the assay results were compared to the described techniques, it was discovered that there was no significant difference in the accuracy and precision of the results. Hence, the developed rapid HPLC method could be employed for the quality control study of a preparation comprising of MET, OFL, and RAC in industries and regulatory authority laboratories.

Funder

Deanship of scientific research, King Faisal University, Al Ahsa, Saudi Arabia

Publisher

MDPI AG

Subject

Filtration and Separation,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3