Benefits of a Mixed-Mode Stationary Phase to Address the Challenging Purification of an Industrially Relevant Peptide: A Proof-of-Concept Study

Author:

Lievore GiulioORCID,Bozza DesireeORCID,Catani MartinaORCID,Cavazzini AlbertoORCID,Chenet TatianaORCID,Pasti LuisaORCID,Ferrazzano LuciaORCID,Cabri WalterORCID,Macis Marco,Ricci AntonioORCID,De Luca ChiaraORCID,Felletti SimonaORCID

Abstract

Peptides are a class of biomolecules with a great potential from the therapeutic point of view, because of their unique biological properties. Industrially, the production stategies adopted produce both the target peptide and a series of impurities that must be removed. Preparative chromatography is the technique of choice for the large-scale purification of biomolecules, generally performed in reversed-phase mode, using hydrophobic adsorbents (e.g., C8 stationary phases). A promising and innovative alternative is represented by mixed-mode columns, which bear two different ligands on the particle surface, exploiting two different retention mechanisms to improve the separation. This work represents a proof-of-concept study focused on the comparison of a hydrophobic adsorbent and a mixed-mode one (bearing both hydrophobic groups and charged ones) for the purification of a crude peptide mixture. Thanks to more-favourable thermodynamics, it was found that, when collecting the whole peak excluding fractions of the peak tail, the mixed-mode column led to an increase in the recovery of roughly +15%, together with a slight improvement in purity at the same time, with respect to the traditional hydrophobic column. In addition, if the whole peak, including the tail, is collected, the performance of the two columns are similar in terms of purity and recovery, but the pepetide elutes as a narrower peak with the mixed mode. This leads to a collection pool showing a much-higher peptide concentration and to lower solvent volumes needed, which is a beneficial achievement when targeting more sustainable processes. These results are very advantageous from the industrial viewpoint, because they also involve a decrease in the peptide amount contained in the peak tail, which must be reprocessed again to satisfy purity requirements.

Publisher

MDPI AG

Subject

Filtration and Separation,Analytical Chemistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3