Magnet Integrated Fabric Phase Sorptive Extraction for the Extraction of Resin Monomers from Human Urine Prior to HPLC Analysis

Author:

Antoniou Georgios1,Alampanos Vasileios1,Kabir Abuzar2ORCID,Zughaibi Torki34ORCID,Furton Kenneth G.2ORCID,Samanidou Victoria1ORCID

Affiliation:

1. Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece

2. International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, Miami, FL 33199, USA

3. Department of Medical Laboratory Sciences, Faculty of Applied Medical Sciences, King Abdulaziz University, Jeddah 21589, Saudi Arabia

4. King Fahd Medical Research Center, King Abdulaziz University, Jeddah 21589, Saudi Arabia

Abstract

In this work, a method for the simultaneous determination of four resin monomers: Bisphenol A, bisphenol A methacrylate glycidate, triethyleneglycol-dimethacrylate, and urethane dimethacrylate, from human urine using magnet integrated fabric phase sorptive extraction (MI-FPSE), followed by high performance liquid chromatography (HPLC) diode array detection (HPLC-DAD), is presented. MI-FPSE is a novel configuration of FPSE that incorporates the stirring and extraction mechanism into one device, resulting in an improved extraction kinetic factor. FPSE is a green sample preparation technique that uses a flexible surface, such as cellulose, coated with a polymeric material using sol–gel technology. Poly(tetrahydrofuran) (PTHF) material was selected, due to its higher efficiency in terms of recovery rate among the studied MI-FPSE membranes. Optimization of the extraction process was performed based on several extraction and elution parameters. The method was validated for its linearity, selectivity, accuracy, precision, and stability of the samples. For the four compounds, the LOD and LOQ were 0.170 ng/μL and 0.050 ng/μL, respectively. The relative standard deviation of the method was less than 9.8% and 11.9%, for the within-day and between-day precision, respectively. The relative recoveries were between 85.6 and 105.2% in all cases, showing a good accuracy. The effectiveness of the proposed method was confirmed through successful application to the bioanalysis of real urine samples.

Publisher

MDPI AG

Subject

Filtration and Separation,Analytical Chemistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3