Analysis of Two Single and Three Double Long-Chain Quaternary Ammonium Compounds via Non-Aqueous Capillary Electrophoresis with Indirect Ultraviolet Detection

Author:

Yao Kai1,Jiang Ruoke12,Wang Ping1,Zhang Jing1,Shao Bing12,Ding Xiaojing12

Affiliation:

1. Beijing Key Laboratory of Diagnostic and Traceability Technologies for Food Poisoning, Beijing Center for Disease Prevention and Control, Beijing 100013, China

2. School of Public Health, Capital Medical University, Beijing 100069, China

Abstract

A novel method utilizing non-aqueous capillary electrophoresis (NACE) with indirect ultraviolet detection (IUD) has been developed for the analysis of five quaternary ammonium compounds (QACs). The QACs analyzed in this study include dodecyl trimethyl ammonium bromide, tetradecyl trimethyl ammonium bromide, dioctyl dimethyl ammonium chloride, octyldecyl dimethyl ammonium chloride and didecyl dimethy ammonium bromide. The separation process was carried out on an uncoated fused quartz capillary with a total length of 50.2 cm (effective length 40.0 cm) and a diameter of 50 μm. The separation buffer consisted of a mixture of MeOH/ACN (90:10, v/v) containing 2 mmol/L sodium acetate, 2 mmol/L trifluoroacetic acid (TFA) and 16 mmol/L dodecyl dimethyl benzyl ammonium chloride. The sample buffer utilized a mixture of MeOH/ACN (20:80, v/v) containing 2 mmol/L TFA. During analysis, a separation voltage of 7 kV was applied, resulting in a current of approximately 2.3 μA. The detection wavelength was set at 214 nm to ensure optimal sensitivity. Under optimal conditions, the method exhibited excellent performance characteristics, with a limit of detection of 0.5 mg/L and a limit of quantitation of 5.0 mg/L for the five QACs. Linear calibration curves were obtained in a concentration range of 5.0 to 100.0 mg/L, with correlation coefficients exceeding 0.999 for all compounds. The recoveries of the five QACs ranged from 92.3% to 114.7%, with relative standard deviations below 7.4%. To assess the applicability of the NACE-IUD method, 17 commercially available samples were successfully analyzed. The results confirmed the suitability of the method for accurate determination of the five QACs in disinfectant products. Notably, this method offers an environmentally friendly approach for the analysis of these QACs.

Funder

Capital’s Funds for Health Improvement and Research

Beijing Municipal Science and Technology Project

Publisher

MDPI AG

Subject

Filtration and Separation,Analytical Chemistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3