Affiliation:
1. School of Chemical and Process Engineering, University of Leeds, Leeds LS2 9JT, UK
2. National Nuclear Laboratory, Central Laboratory, Seascale CA20 1PG, UK
Abstract
This work reports the effect of scaling up annular centrifugal contactors (ACCs) upon the residence time distribution and the efficiency of extraction of uranium. The experiments were carried out in a multi-scale ACC platform of three ACCs with rotor diameters of 12, 25, and 40 mm. To enable direct comparison across all three scales of ACC, the residence time distributions were acquired by injecting dye into the solvent phase at a constant relative volume related to the ACC liquid holdup. Across all scales and flowrates, there was little difference in residence time distribution (<6 residence volumes), except for the smallest 12 mm rotor diameter ACC with a high solvent/aqueous feed ratio, which required 12 residence volumes, potentially due to internal circulation in the annulus. At low flowrates, the stage efficiency in all cases was >95%, and it improved further in larger rotor diameter ACCs.
Funder
the £46M Advanced Fuel Cycle Programme as part of the Department for Business, Energy and Industrial Strategy’s (BEIS) £505m Energy Innovation Programme
Engineering and Physical Sciences Research Council
Subject
Filtration and Separation,Analytical Chemistry
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献