A Sensitive, Simple, and Fast LC–MS/MS Method for Quantification of Remifentanil in Human Plasma: Applications in Critically Ill Patients’ Plasma during Extracorporeal Membrane Oxygenation

Author:

Chae Soon Uk1,Kim Ji Seon1,Lee Chae Bin1,Jo Seong Jun1,Min Kyung Lok2,Chang Min Jung2ORCID,Bae Soo Kyung1ORCID

Affiliation:

1. College of Pharmacy and Integrated Research Institute of Pharmaceutical Sciences, The Catholic University of Korea, 43 Jibong-ro, Bucheon-si 14662, Republic of Korea

2. Department of Pharmacy and Yonsei Institute of Pharmaceutical Sciences, College of Pharmacy, Yonsei University, Incheon 21983, Republic of Korea

Abstract

A sensitive, simple, and fast liquid chromatography–tandem mass spectrometry (LC–MS/MS) bioanalytical method was developed to determine remifentanil in human plasma and prevent its instability by esterases during quantification. A 20 μL sample of human plasma, acidified with formic acid, was precipitated using 100 μL of acetonitrile. Chromatography was carried out on an Agilent Poroshell 120 EC-C18 column (4.6 × 50 mm, 2.7 μm) with an isocratic elution by acetonitrile and distilled water containing 0.1% formic acid (65:35, v/v) at a flow rate of 0.5 mL/min. Transition ions were detected as m/z 377.10→113.20 and m/z 277.00→111.00 for remifentanil and chlorpropamide (internal standard), respectively, with positive electrospray ionization in mass spectrometry. The run time was only 3 min per sample. We evaluated the selectivity, linearity, carry-over, accuracy, precision, extraction recovery, absolute matrix effect, stability, and incurred sample reanalysis and found that all these parameters were within acceptable limits. The calibration curve range for remifentanil was 0.05–50 ng/mL with regression coefficient (r) values higher than 0.9939. Given the simple and fast sample preparation and the lower LLOQ concentration compared to those in other methods, this method was successfully used to quantify plasma levels after intravenous infusion of remifentanil to intensive-care-unit patients during extracorporeal membrane oxygenation.

Funder

Ministry of Education

Ministry of Health & Welfare

Publisher

MDPI AG

Subject

Filtration and Separation,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3