Diagnosis of Osteoarthritis at an Early Stage via Infrared Spectroscopy Combined Chemometrics in Human Serum: A Pilot Study

Author:

Aziz Atiqah Ab1,Selvaratnam Veenesh2ORCID,Fikri Yasmin Fadzlin Binti Ahmad1,Sani Muhamad Shirwan Abdullah3ORCID,Kamarul Tunku14

Affiliation:

1. Tissue Engineering Group (TEG), National Orthopaedic Centre of Excellence for Research and Learning (NOCERAL), Department of Orthopaedic Surgery, Faculty of Medicine, Universiti Malaya, Kuala Lumpur 50603, Malaysia

2. Joint Reconstruction Unit (JRU), National Orthopaedic Centre of Excellence in Research and Learning (NOCERAL), Department of Orthopaedic Surgery, Faculty of Medicine, Universiti Malaya, Kuala Lumpur 50603, Malaysia

3. International Institute for Halal Research and Training, Level 3, KICT Building, International Islamic University Malaysia (IIUM), Kuala Lumpur 53100, Malaysia

4. Advanced Medical and Dental Institute (AMDI), Universiti Sains Malaysia, Bertam 13200, Malaysia

Abstract

Methods applied for early diagnosis of osteoarthritis (OA) are limited. Early prevention and treatment can effectively reduce the pain of OA patients and save costs. The present study aimed to develop a rapid non-destructive detection method for early diagnosis of OA by evaluating infrared (IR) spectroscopy combined chemometrics. Our cohort consisted of (a) 15 patients with osteoarthritis (OA) and (b) 10 without clinical signs of the disease and they were used as controls. Attenuated total reflection Fourier-transform infrared (ATR-FTIR) spectroscopy was used to investigate serum samples (50 µL) collected from these patients. A supervised classification algorithm namely discriminant analysis (DA) was applied to evaluate the diagnostic accuracy spectral processing and chemometrics analysis allowed for detecting spectral biomarkers that discriminated the two cohorts. About 250 infrared spectra were statistically important for separating the groups. Peaks at 1000 cm−1 in OA serum were associated mainly with C–O stretching vibration associated with the changes in the proteoglycan contents previously reported in OA. A good overall classification accuracy of 74.47% was obtained from the DA model. Our findings indicated that this discriminating model, which incorporated the ATR-FTIR spectrum, could provide a rapid and cost-effective blood test, thus facilitating the early diagnosis of human OA.

Publisher

MDPI AG

Subject

Process Chemistry and Technology,Chemical Engineering (miscellaneous),Bioengineering

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3