Performance Analysis of a Waste Heat Recovery System for a Biogas Engine Using Waste Resources in an Industrial Complex

Author:

Cho Kyung-Chul12,Shin Ki-Yeol1ORCID,Shim Jaesool1,Bae San-Su3,Kwon Oh-Dae4

Affiliation:

1. School of Mechanical Engineering, Yeungnam University, Gyeongsan 38541, Republic of Korea

2. Energy System Research Center, Korea Textile Machinery Convergence Research Institute, Gyeongsan 38542, Republic of Korea

3. Daekyung Energy Engineering Co., Ltd., Seoul 08591, Republic of Korea

4. Four-One System Co., Ltd., Gyeongsan 38539, Republic of Korea

Abstract

To achieve carbon neutrality and address global energy supply issues by 2050, there is active progress in the industrial sector for waste energy recovery and commercialization projects. It is necessary to consider both the energy recovery efficiency and economic feasibility based on the production volume for the resource utilization of waste energy, along with eco-friendly processing methods. In this study, a waste heat recovery system was designed to recover a large amount of thermal energy from high-temperature exhaust gases of gas engines for power generation by using biogas produced from organic waste in industrial complexes. Types and sizes of components for a waste heat recovery system that were suitable for various engine sizes depending on biogas production were designed, and the energy recovery efficiency was analyzed. The waste heat recovery system consisted of a smoke tube boiler that generated superheated steam at 161 °C under 490 kPa of pressure from the exhaust gas as the heat source, along with two economizers for heating both supply water and hot water. Heat exchangers that were suitable for three different engine sizes were configured, and their performance and energy flow were calculated. In particular, when operating two engines with a power output of 100 kW, the boiler showed the highest steam production efficiency, and the superheated steam production from high-temperature exhaust gas at 600 °C was designed to be 191 kg/h, while hot water at 58 °C was designed to be produced at 1000 kg/h. In addition, further research on the heat exchanger capacity ratio confirmed that it was within a certain range despite the difference in heat exchanger capacity and efficiency depending on the engine size. It was confirmed that the heat exchange capacity ratio of the boiler was important as an optimal-capacity design value for the entire system, as it ranged from 46% to 47% of the total heat exchanger size.

Funder

Korea Institute of Energy Technology Evaluation and Planning (KETEP) funded by the Korean government

Publisher

MDPI AG

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3