Cross-Borehole ERT Monitoring System for CO2 Geological Storage: Laboratory Development and Validation

Author:

Jia Ninghong1,Wu Chenyutong2,He Chang1,Lv Weifeng1,Ji Zemin1,Xing Lanchang2ORCID

Affiliation:

1. State Key Laboratory of Enhanced Oil Recovery, Research Institute of Petroleum Exploration and Development, PetroChina, Beijing 100083, China

2. College of Control Science and Engineering, China University of Petroleum (East China), Qingdao 266580, China

Abstract

Cross-borehole electrical resistivity tomography (CHERT) technology has been implemented in field-scale CCS/CCUS (carbon capture and storage/carbon capture, utilization and storage) projects. It is highly desirable to investigate how to optimize the design of the ERT electrode arrays and corresponding working schemes for both laboratory experiments and field applications. A CHERT system was developed for laboratory experiments of CO2 geological storage applications. An optimization method was established for optimizing the structure of electrode arrays and corresponding working schemes. The developed CHERT system was calibrated systematically to determine the measurement range and accuracy of electrical impedance. Laboratory experiments were designed and implemented to validate the performance of the developed CHERT system. It has been illustrated that: (1) It is an essential step to optimize the structure of electrode arrays and corresponding working schemes of CHERT according to the real application background. The optimization method based on finite-element modelling provides an effective means for designing a field-scale CHERT system. (2) The quality of the images inverted from the CHERT data is highly dependent on the working schemes and specific modes, which is closely related to the size of the data sets used for the inversion. The AM-BN scheme is recommended due to the better uniformity of the resultant sensitivity field and application to larger borehole spacing. (3) Based on the calibration, the measurement range of the developed CHERT system can be determined as 100 Ω to 4.5 kΩ with an error limit of 1.5%. The maximum relative errors of the impedance magnitude and phase angle are 5.0% and 7.0%, respectively. Based on the test results the location of the CO2-bearing objects can be identified accurately. The shapes of the tested objects present distortion to some extent, but this can be alleviated by selecting working modes with a larger size of data set.

Funder

Major Special Science and Technology Project of CNPC

State Scholarship Fund of China Scholarship Council

Yazhou Bay Elite talents Science and Technology Project

Innovation Fund of CNPC

Shandong Provincial Natural Science Foundation

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3