Customised Implant for Temporomandibular Joint: New Technique to Design and Stress Analysis to Balance the Loading at Both Ends

Author:

Tiwari Anubhav1ORCID,Ahmed Ishfaq A.1ORCID,Gupta Vijay Kumar1ORCID,Haldkar Rakesh Kumar2ORCID,Parinov Ivan A.2ORCID

Affiliation:

1. Machine Dynamics and Vibration Lab, Discipline of Mechanical Engineering, PDPM Indian Institute of Information Technology, Design & Manufacturing, Jabalpur, Dumna Airport Road, Jabalpur 482005, India

2. I. I. Vorovich Mathematics, Mechanics and Computer Sciences Institute, Southern Federal University, Rostov-on-Don 344090, Russia

Abstract

The temporomandibular joint (TMJ) is a critical joint for the opening and closing of the mouth. The generation of customised TMJs according to individuals’ dental anatomy is needed. Currently, the implants available on the market lack consideration of the patient’s dental anatomy. This leads to the creation of an imbalance in the reaction forces on both ends of the TMJ. This requires a slight structural change in the design parameters to give a solution. The purpose of this study is to propose a new design that includes the geometry and materials for a TMJ implant. Stress analysis was carried out on the TMJ to balance the reaction forces at both TMJ ends. A static analysis was performed using ANSYS Workbench, to compare the results of two customised designs of TMJ implants, in order to better balance the reaction forces at both ends. The model in the study showed that the reaction forces for both the patient-specific TMJ implants were nearly balanced. The reaction forces were better balanced, and almost equivalent to the intact conditions. The stresses in the mandible were more uniformly distributed in the customised design of the TMJ implant. The two types of design showed that the custom design took up less space in the patient’s region of surgery, making it a better option compared to a stock TMJ implant. The custom implant would allow faster patient rehabilitation, as the reaction forces would be close to those in intact conditions.

Funder

Ministry of Science and Higher Education of the Russian Federation

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Mechanical Engineering,Control and Systems Engineering

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3