The Accuracy of Zygomatic Implant Placement Assisted by Dynamic Computer-Aided Surgery: A Systematic Review and Meta-Analysis

Author:

Fan Shengchi12ORCID,Sáenz-Ravello Gustavo3ORCID,Diaz Leonardo4,Wu Yiqun2,Davó Rubén5,Wang Feng2,Magic Marko6ORCID,Al-Nawas Bilal1ORCID,Kämmerer Peer W.1ORCID

Affiliation:

1. Department of Oral and Maxillofacial Surgery, Plastic Operations, University Medical Center Mainz, 55131 Mainz, Germany

2. Second Dental Clinic, Ninth People’s Hospital, College of Stomatology, Shanghai Jiao Tong University, School of Medicine, National Clinical Research Center for Oral Disease, Shanghai Key Laboratory of Stomatology, Shanghai Research Institute of Stomatology, Shanghai 200011, China

3. Center for Epidemiology and Surveillance of Oral Diseases (CESOD), Faculty of Dentistry, Universidad de Chile, Santiago 8380420, Chile

4. Postgraduate School, Faculty of Dentistry, Universidad de Chile, Santiago 8380420, Chile

5. Department of Implantology and Maxillofacial Surgery, Vithas Davó Instituto Dental, 03016 Alicante, Spain

6. School of Dental Medicine, University of Belgrade, 11000 Belgrade, Serbia

Abstract

Purpose: The present systematic review aimed to investigate the accuracy of zygomatic implant (ZI) placement using dynamic computer-aided surgery (d-CAIS), static computer-aided surgery (s-CAIS), and a free-hand approach in patients with severe atrophic edentulous maxilla and/or deficient maxilla. Methods: Electronic and manual literature searches until May 2023 were performed in the PubMed/Medline, Scopus, Cochrane Library, and Web of Science databases. Clinical trials and cadaver studies were selected. The primary outcome was planned/placed deviation. Secondary outcomes were to evaluate the survival of ZI and surgical complications. Random-effects meta-analyses were conducted and meta-regression was utilized to compare fiducial registration amounts for d-CAIS and the different designs of s-CAIS. Results: A total of 14 studies with 511 ZIs were included (Nobel Biocare: 274, Southern Implant: 42, SIN Implant: 16, non-mentioned: 179). The pooled mean ZI deviations from the d-CAIS group were 1.81 mm (95% CI: 1.34–2.29) at the entry point and 2.95 mm (95% CI: 1.66–4.24) at the apex point, and angular deviations were 3.49 degrees (95% CI: 2.04–4.93). The pooled mean ZI deviations from the s-CAIS group were 1.19 mm (95% CI: 0.83–1.54) at the entry point and 1.80 mm (95% CI: 1.10–2.50) at the apex point, and angular deviations were 2.15 degrees (95% CI: 1.43–2.88). The pooled mean ZI deviations from the free-hand group were 2.04 mm (95% CI: 1.69–2.39) at the entry point and 3.23 mm (95% CI: 2.34–4.12) at the apex point, and angular deviations were 4.92 degrees (95% CI: 3.86–5.98). There was strong evidence of differences in the average entry, apex, and angular deviation between the navigation, surgical guide, and free-hand groups (p < 0.01). A significant inverse correlation was observed between the number of fiducial screws and the planned/placed deviation regarding entry, apex, and angular measurements. Conclusion: Using d-CAIS and modified s-CAIS for ZI surgery has shown clinically acceptable outcomes regarding average entry, apex, and angular deviations. The maximal deviation values were predominantly observed in the conventional s-CAIS. Surgeons should be mindful of potential deviations and complications regardless of the decision making in different guide approaches.

Funder

ITI research

FGD

Publisher

MDPI AG

Subject

General Medicine

Reference51 articles.

1. Zygoma fixture in the management of advanced atrophy of the maxilla: Technique and long-term results;Nilsson;Scand. J. Plast. Reconstr. Surg. Hand Surg.,2004

2. Survival and Complications of Zygomatic Implants: An Updated Systematic Review;Chrcanovic;J. Oral Maxillofac. Surg.,2016

3. 5-year outcome of cross-arch prostheses supported by four immediately loaded zy-gomatic implants: A prospective case series;Pons;Eur. J. Oral. Implantol.,2015

4. Quad Zygoma: Technique and Realities;David;Oral. Maxillofac. Surg. Clin. N. Am.,2019

5. Immediate function in the atrophic maxilla using zygoma implants: A pre-liminary study;Davo;J. Prosthet. Dent.,2007

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3