Improving Quality Assurance in a Radiation Oncology Using ARIA Visual Care Path

Author:

Bonaparte Ilaria1,Fragnoli Federica1,Gregucci Fabiana1,Carbonara Roberta1,Di Guglielmo Fiorella Cristina1,Surgo Alessia1ORCID,Davì Valerio1,Caliandro Morena1,Sanfrancesco Giuseppe1,De Pascali Christian1,Aga Alberto1,Indellicati Chiara1,Parabita Rosalinda1,Cuscito Rosilda1,Cardetta Pietro1,Laricchia Maurizio1,Antonicelli Michele1,Ciocia Annarita1,Curci Domenico1,Guida Pietro1,Ciliberti Maria Paola1,Fiorentino Alba12ORCID

Affiliation:

1. Department of Radiation Oncology, Miulli General Regional Hospital, 70021 Bari, Italy

2. Department of Medicine and Surgery, LUM University, 70010 Bari, Italy

Abstract

Purpose: Errors and incidents may occur at any point within radiotherapy (RT). The aim of the present retrospective analysis is to evaluate the impact of a customized ARIA Visual Care Path (VCP) on quality assurance (QA) for the RT process. Materials and Methods: The ARIA VCP was implemented in June 2019. The following tasks were customized and independently verified (by independent checks from radiation oncologists, medical physics, and radiation therapists): simulation, treatment planning, treatment start verification, and treatment completion. A retrospective analysis of 105 random and unselected patients was performed, and 945 tasks were reviewed. Patients’ reports were categorized based on treatment years period: 2019–2020 (A); 2021 (B); and 2022–2023 (C). The QA metrics included data for timeliness of task completion and data for minor and major incidents. The major incidents were defined as incorrect prescriptions of RT dose, the use of different immobilization systems during RT compared to the simulation, the absence of surface-guided RT data for patients’ positioning, incorrect dosimetric QA for treatment plans, and failure to complete RT as originally planned. A sample size of approximately 100 was able to obtain an upper limit of 95% confidence interval below 5–10% in the case of zero or one major incident. Results: From June 2019 to December 2023, 5300 patients were treated in our RT department, an average of 1300 patients per year. For the purpose of this analysis, one hundred and five patients were chosen for the study and were subsequently evaluated. All RT staff achieved a 100% compliance rate in the ARIA VCP timely completion. A total of 36 patients were treated in Period A, 34 in Period B, and 35 in Period C. No major incidents were identified, demonstrating a major incident rate of 0.0% (95% CI 0.0–3.5%). A total of 26 out of 945 analyzed tasks (3.8%) were reported as minor incidents: absence of positioning photo in 32 cases, lack of patients’ photo, and absence of plan documents in 4 cases. When comparing periods, incidents were statistically less frequent in Period C. Conclusions: Although the present analysis has some limitations, its outcomes demonstrated that software for the RT workflow, which is fully integrated with both the record-and-verify and treatment planning systems, can effectively manage the patient’s care path. Implementing the ARIA VCP improved the efficiency of the RT care path workflow, reducing the risk of major and minor incidents.

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3