Diagnostic Performance of Serial High-Sensitivity Cardiac Troponin Measurements in the Emergency Setting

Author:

Kavsak Peter A.ORCID,Hewitt Mark K.ORCID,Mondoux Shawn E.,Cerasuolo Joshua O.,Ma Jinhui,Clayton Natasha,McQueen Matthew,Griffith Lauren E.,Perez Richard,Seow HsienORCID,Ainsworth CraigORCID,Ko Dennis T.,Worster Andrew

Abstract

Serial high-sensitivity cardiac troponin (hsTn) testing in the emergency department (ED) and the intensive cardiac care unit may assist physicians in ruling out or ruling in acute myocardial infarction (MI). There are three major algorithms proposed for high-sensitivity cardiac troponin I (hsTnI) using serial measurements while incorporating absolute concentration changes for MI or death following ED presentation. We sought to determine the diagnostic estimates of these three algorithms and if one was superior in two different Canadian ED patient cohorts with serial hsTnI measurements. An undifferentiated ED population (Cohort-1) and an ED population with symptoms suggestive of acute coronary syndrome (ACS; Cohort-2) were clinically managed with non-hsTn testing with the hsTnI testing performed in real-time with physicians blinded to these results (i.e., hsTnI not reported). The three algorithms evaluated were the European Society of Cardiology (ESC), the High-STEACS pathway, and the COMPASS-MI algorithm. The diagnostic estimates were derived for each algorithm for the 30-day MI/death outcome for the rule-out and rule-in arm in each cohort and compared to proposed diagnostic benchmarks (i.e., sensitivity ≥ 99.0% and specificity ≥ 90.0%) with 95% confidence intervals (CI). In Cohort-1 (n = 2966 patients, 15.3% had outcome) and Cohort-2 (n = 935 patients, 15.6% had outcome), the algorithm that obtained the highest sensitivity (97.8%; 95% CI: 96.0–98.9 and 98.6%; 95% CI: 95.1–99.8, respectively) in both cohorts was COMPASS-MI. Only Cohort-2 with both the ESC and COMPASS-MI algorithms exceeded the specificity benchmark (97.0%; 95% CI: 95.5–98.0 and 96.7%; 95% CI: 95.2–97.8, respectively). Patient selection for serial hsTnI testing will affect specificity estimates, with no algorithm achieving a sensitivity ≥ 99% for 30-day MI or death.

Funder

Canadian Institutes of Health Research

Publisher

MDPI AG

Subject

Pharmacology (medical),General Pharmacology, Toxicology and Pharmaceutics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3