Affiliation:
1. School of Civil and Environmental Engineering, Harbin Institute of Technology, University Town, Shenzhen 518055, China
2. Guangdong Provincial Key Laboratory of Intelligent and Resilient Structures for Civil Engineering, Harbin Institute of Technology, Shenzhen 518055, China
3. Central Research Institute of Building and Construction Co., Ltd., MCC Group, Shenzhen 518055, China
Abstract
In the paper, the eccentric compression behavior of the truss-reinforced cross-shaped concrete-filled steel tubular (CCFST) column is investigated. A total of eighteen CCFST columns were tested under eccentric compression, and the key test variables included the reinforced truss node spacing (s = 140 mm and 200 mm), slenderness ratio (λ = 9.2, 16.6, and 23.1), and eccentricity ratio (η = 0, 0.08, and 0.15). The failure mode, deformation characteristic, stress distribution, strain distribution at the mid-span of the steel tube, and the eccentric compression bearing capacity were assessed. The results show that due to the addition of reinforced truss, the steel plates near the mid-span of eccentrically compressed CCFST columns experienced multi-wave buckling rather than single-wave buckling after the peak load was reduced to 85%, and the failure mode of concrete also changed from single-section to multi-section collapse failure. Comparisons were made with the unstiffened specimen. The ductility coefficient of the stiffened specimen with eccentricity ratios of 0.08–0.15 and node spacings of 140 mm~200 mm increased by 70~83%, approaching that of the multi-cell specimens with an increasing steel ratio of 1.8%. In addition, by comparing the test results with the calculation results of four domestic and international design codes, it was found that the Chinese codes CECS159-2018 and GB50936-2014, and the Eurocode 4 (2004) can be better employed to predict the compression bearing capacity of truss-reinforced CCFST columns.
Funder
Special Projects of Science and Technology of CHINA MINMETALS CORPORATION