Indoor Air Quality and Smoking Control in Healthcare Environments in Northern China

Author:

Zhang Shuya123,Song Kexin123,Ban Qichao123,Gong Puyue24,Li Ruisi3,Peng Zhen3

Affiliation:

1. Innovation Institute for Sustainable Maritime Architecture Research and Technology (iSMART), Qingdao University of Technology, Qingdao 266033, China

2. Shandong Engineering Research Center of City Information Modeling, Qingdao 266033, China

3. College of Architecture and Urban Planning, Qingdao University of Technology, Qingdao 266033, China

4. Department of Urban Planning and Design, Xi’an Jiaotong-Liverpool University, Suzhou 215123, China

Abstract

Background: Air pollution has adverse effects on human health, while people experience regular contact with air pollutants in a high concentration via inhalation and ingestion. Nowadays, the average person spends more than 90% of their lifetime inside both private and public buildings, and this figure can reach close to 100% for the sick or elderly who cannot take care of themselves. Attention should be paid to indoor air quality (IAQ), especially for certain groups in specific places. Purpose: This study intends to investigate indoor air quality in a large general hospital in Northern China, where people desire clean air for good nursing, and then propose solutions to any air pollution present. Methods: Some influential factors related to air pollution, including PM2.5 and PM10, were measured in winter. Observations were applied to indicate that the smoking behaviors of medical staff were an important contributor to air pollution. Experimental measurements were designed to test the concentration of airborne nicotine. Questionnaire surveys and follow-up interviews were conducted to understand attitudes towards smoking behaviors and offer design strategies. Results: The scopes of 24 h mean concentrations of PM2.5 (10.2~57.8 µg/m3, 17.5~45.5 µg/m3, and 20.5~91.1 µg/m3) and PM10 (17.7~81.8 µg/m3, 13.0~83.8 µg/m3, and 31.7~188.1 µg/m3) exceeded relevant guideline values, and the airborne nicotine concentrations (1.29 µg/m3 and 1.62 µg/m3) confirmed that smoking behaviors occurred in the consulting room. Conclusions: To control tobacco to ensure good indoor air quality, smoking behaviors should be managed instead of forbidden. This will also provide greater satisfaction to medical staff. Smoking behavior management requires a comprehensive consideration based on ambient conditions and psychological demands. As there is a lack of specific requirements in relevant design regulations that are tailored to ensure the environmental satisfaction of medical staff, the findings from this study can be used as evidence to inform the design of healthcare environments for public health in future.

Funder

National Natural Science Foundation of China

Natural Science Foundation of Shandong Province

Publisher

MDPI AG

Subject

Management, Monitoring, Policy and Law,Renewable Energy, Sustainability and the Environment,Geography, Planning and Development,Building and Construction

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3