Abstract
The development of hydrogen energetics is a possible way to reduce emissions of harmful substances into the atmosphere in the production of electricity. Its implementation requires the introduction of energy facilities capable of operating on environmentally safe fuel. At the same time, from a technological point of view, it is easier to implement a gradual shift to the use of hydrogen in power plants by burning methane–hydrogen blends. This paper presents the results of thermodynamic studies of the influence of the chemical composition of the methane–hydrogen blend on the performance of binary and trinary power units. It is shown that an increase in the hydrogen volume fraction in the fuel blend from 0 to 80% leads to a decrease in the Wobbe index by 16% and an increase in the power plant auxiliaries by almost 3.5 times. The use of a trinary CCGT unit with a single-circuit WHB and working fluid water condensation makes it possible to increase the net efficiency by 0.74% compared to a binary CCGT with a double-circuit WHB and a condensate gas heater.