Author:
Kliukas Romualdas,Jaras Arūnas,Lukoševičienė Ona
Abstract
The current research paper is focused on the experimental investigation of features of chemical admixtures (superplasticizers C-3, ‘Dofen’ and formaldehyde resin ACF-3M) utilizing in reinforced spun concrete structures. For the sake of comparison, the results of studying the effects of chemical admixtures on physical and mechanical properties on vibrated and spun concrete are provided. As a separate part of spun concrete products, the supporting poles of overhead power lines are introduced. The results obtained indicate, that the positive effect of chemical admixtures for spun and vibrated concrete is most pronounced at an early age of concrete. The effective amount of chemical admixtures for spun concrete is 0.15% of cement mass when formaldehyde resin ACF-3M and 1% of cement mass when superplasticizers C-3 and ‘Dofen’ are used. Moreover, the brief review about the reinforced spun concrete members is provided.
Subject
General Materials Science
Reference38 articles.
1. Spun Concrete Poles for Electrical Transmission Structure Applications — Continuing to Push the Envelope of the Technology
2. Utilising of Precast Reinforced Concrete in the Construction of Electrical Power Networks of 35-500 Kv;Reut,1962
3. EN 12843:2005 Precast Concrete Products—Masts and Poles,2005
4. Guidelines for the Design, Manufacture and Use of Reinforced Concrete Centrifuged Structures of Annular Cross Section,1979
5. Standard Specification for Spun Cast Prestressed Concrete Poles,2019
Cited by
9 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献