This work describes the development of a reusable 2D detector based on radiochromic reaction for radiotherapy dosimetric measurements. It consists of a radiochromic gel dosimeter in a cuboidal plastic container, scanning with a flatbed scanner, and data processing using a dedicated software package. This tool is assessed using the example of the application of the coincidence test of radiation and mechanical isocenters for a medical accelerator. The following were examined: scanning repeatability and image homogeneity, the impact of image processing on data processing in coincidence tests, and irradiation conditions—monitor units per radiation beam and irradiation field are selected. Optimal conditions for carrying out the test are chosen: (i) the multi-leaf collimator gap should preferably be 5 mm for 2D star shot irradiation, (ii) it is recommended to apply ≥2500–≤5000 MU per beam to obtain a strong signal enabling easy data processing, (iii) Mean filter can be applied to the images to improve calculations. An approach to dosimeter reuse with the goal of reducing costs is presented; the number of reuses is related to the MUs per beam, which, in this study, is about 5–57 for 30,000–2500 MU per beam (four fields). The proposed reusable system was successfully applied to the coincidence tests, confirming its suitability as a new potential quality assurance tool in radiotherapy.

Publisher

MDPI AG

Reference38 articles.

1. Slotman, B.J., Solberg, T.D., and Verellen, D. (2005). Extracranial Stereotactic Radiotherapy and Radiosurgery, Taylor & Francis.

2. Daniel, M.T., Samuel, T.C., Arjun, S., and Jason, P.S. (2019). Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy: A Comprehensive Guide, Springer Nature.

3. (2015). Quality Control of Medical Electron Accelerators, Available online: https://ssrpm.ch/wp-content/uploads/2014/08/r11qca-e.pdf.

4. Task group 142 report: Quality assurance of medical accelerators (and consultants: Sandin C, Holmes T);Klein;Med. Phys.,2009

5. What do we mean when we talk about the linac isocenter?;Zhang;Int. J. Med. Phys. Clin. Eng. Radiat. Oncol.,2015