High Performance Size Exclusion Chromatography-Inductively Coupled Plasma-Mass Spectrometry to Study the Copper and Cadmium Complexation with Humic Acids

Author:

Radaelli MartaORCID,Scalabrin ElisaORCID,Toscano Giuseppa,Capodaglio Gabriele

Abstract

Dissolved organic matter (DOM) plays an important role in the environment by influencing the transport and distribution of organic and inorganic components through different processes: the retention, mobilization, and bio-availability of potentially toxic elements (PTEs). The aim of the present study is to examine the dimensional characterization of humic acids (HA) extracted from soil matrix, as well as to analyze the metal distribution among different ligand classes. The molecular size distribution of the HA extract from soil showed three dimensional classes: 52 KDa, 4.5 KDa, and 900 Da. HPSEC-ICP-MS measurements demonstrated that the dimensional classes, relative to first two fractions, bind the largest part of metals. The complexing capacity of HA was evaluated to assess the pollutants mobility in the environmental system. In particular, cadmium (Cd) and copper (Cu) complexation was investigated due to the great concern regarding their bio-availability and toxicity in natural waters. The complexing capacity of HA solution (20 mg/L) was measured by titration using a high-performance size exclusion chromatography (HP-SEC) coupled to an inductively coupled mass spectrometry (ICP-MS). Results obtained by this technique are compared with those obtained by anodic stripping voltammetry (ASV) to investigate the effects of kinetic lability of complexes on measurements carried by HPSEC-ICP-MS. In this study, results of ligand concentrations and stability constants obtained via the two techniques are assessed considering the detection window associated to the applied analytical methodology. Results obtained using the two analytical techniques showed that Cd is complexed by two classes of ligands. However, the ligand concentration values obtained using the two techniques are different, because the detection window associated to the two methodologies; the complexing capacity, which was obtained as sum of the two classes of ligands, were 33 nmol/L and 9 nmol/L for ASV and HPSEC-ICP-MS, respectively. The copper complexing capacities determined by the two methodologies are comparable: 166 and 139 nmol/L for ASV and HPSEC-ICP-MS, respectively. However, the results of Cu titration differ for the two techniques, highlighting only one class of ligands when ASV was used, and two classes when HPSEC-ICP-MS was employed. Differences on results obtained by the two techniques are explained considering the kinetic lability of complexes; the results show that, differently from previous studies, also Cu complexes can be kinetically labile, if one technique with high reaction time is used, as well some cadmium complexes are sufficient stable to be determined by HPSEC-ICP-MS.

Publisher

MDPI AG

Subject

Chemistry (miscellaneous),Analytical Chemistry,Organic Chemistry,Physical and Theoretical Chemistry,Molecular Medicine,Drug Discovery,Pharmaceutical Science

Cited by 13 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3