On the Use of Deuterated Organic Solvents without TMS to Report 1H/13C NMR Spectral Data of Organic Compounds: Current State of the Method, Its Pitfalls and Benefits, and Related Issues

Author:

Nazarski Ryszard B.1ORCID

Affiliation:

1. Theoretical and Structural Chemistry Group, Department of Physical Chemistry, Faculty of Chemistry, University of Lodz, 163/165 Pomorska, 90-236 Łódź, Poland

Abstract

The quite popular, simple but imperfect method of referencing NMR spectra to residual 1H and 13C signals of TMS-free deuterated organic solvents (referred to as Method A) is critically discussed for six commonly used NMR solvents with respect to their δH and δC values that exist in the literature. Taking into account the most reliable data, it was possible to recommend ‘best’ δX values for such secondary internal standards. The position of these reference points on the δ scale strongly depends on the concentration and type of analyte under study and the solvent medium used. For some solvents, chemically induced shifts (CISs) of residual 1H lines were considered, also taking into account the formation of 1:1 molecular complexes (for CDCl3). Typical potential errors that can occur as a result of improper application of Method A are considered in detail. An overview of all found δX values adopted by users of this method revealed a discrepancy of up to 1.9 ppm in δC reported for CDCl3, most likely caused by the CIS mentioned above. The drawbacks of Method A are discussed in relation to the classical use of an internal standard (Method B), two ‘instrumental’ schemes in which Method A is often implicitly applied, that is, the default Method C using 2H lock frequencies and Method D based on Ξ values, recommended by the IUPAC but only occasionally used for 1H/13C spectra, and external referencing (Method E). Analysis of current needs and opportunities for NMR spectrometers led to the conclusion that, for the most accurate application of Method A, it is necessary to (a) use dilute solutions in a single NMR solvent and (b) to report δX data applied for the reference 1H/13C signals to the nearest 0.001/0.01 ppm to ensure the precise characterization of new synthesized or isolated organic systems, especially those with complex or unexpected structures. However, the use of TMS in Method B is strongly recommended in all such cases.

Publisher

MDPI AG

Subject

Chemistry (miscellaneous),Analytical Chemistry,Organic Chemistry,Physical and Theoretical Chemistry,Molecular Medicine,Drug Discovery,Pharmaceutical Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3