New Trend in Toxicological Screening Using Volumetric Absorptive Microsampling (VAMS) and High-Resolution Mass Spectrometry (HR/MS) Combination

Author:

Houzé Pascal12,Borowski Ilona1,Bito Eugénie1,Magny Romain13,Morcos Athina1,Voicu Sebastian34,Mégarbane Bruno34ORCID,Labat Laurence14ORCID

Affiliation:

1. Laboratory of Toxicology, Federation of Toxicology, Lariboisière Hospital, Assistance Publique-Hôpitaux de Paris (AP-HP), 10 rue Ambroise Paré, 75010 Paris, France

2. Chemical and Biological Health Technologies Unit (UTCBS), CNRS UMR8258-U1022, University of Paris, 4 Avenue de l’Observatoire, 75006 Paris, France

3. INSERM UMRS-1144, University of Paris, 4 Avenue de l’Observatoire, 75006 Paris, France

4. Department of Medical and Toxicological Critical Care, Federation of Toxicology, Lariboisière Hospital, Assistance Publique-Hôpitaux de Paris (AP-HP), 10 rue Ambroise Paré, 75010 Paris, France

Abstract

In toxicology, screenings are routinely performed using chromatographic methods coupled to detection systems such as high-resolution mass spectrometry (HR/MS). The increase in specificity and sensitivity of HRMS is responsible for the development of methods for alternative samples such as Volumetric Adsorptive Micro-Sampling. Whole blood overloaded with 90 drugs was sampled with 20 µL MitraTM to optimize the pre-analytical step as well as to determine the identification limits of drugs. Elution of chemicals was carried out in a solvent mixture through agitation and sonication. After dissolution, 10 μL was injected into the chromatographic system coupled to the OrbitrapTM HR/MS. Compounds were confirmed against the laboratory library. The clinical feasibility was assessed in fifteen poisoned patients using the simultaneous sampling of plasma, whole blood and MitraTM. The optimized extraction procedure allowed us to confirm 87 compounds out of the 90 present in the spiked whole blood. Cannabis derivatives were not detected. For 82.2% of the investigated drugs, the identification limits were below 12.5 ng·mL−1, with the extraction yields ranging from 80.6 to 108.7%. Regarding the patients’ analysis, 98% of the compounds in plasma were detected in MitraTM compared to whole blood, with a satisfying concordance (R2 = 0.827). Our novel screening approach opens new insights into different toxicologic fields appropriate for pediatrics, forensics or to perform mass screening.

Publisher

MDPI AG

Subject

Chemistry (miscellaneous),Analytical Chemistry,Organic Chemistry,Physical and Theoretical Chemistry,Molecular Medicine,Drug Discovery,Pharmaceutical Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3