Affiliation:
1. Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia
2. Department of Chemistry, College of Science, King Saud University, Riyadh 11495, Saudi Arabia
Abstract
Gemcitabine is a chemotherapeutic agent used to treat various malignancies, including breast and bladder cancer. In the current study, three innovative selective gemcitabine hydrochloride sensors are developed using 4-tert-butylcalix-[8]-arene (sensor 1), β-cyclodextrin (sensor 2), and γ-cyclodextrin (sensor 3) as ionophores. The three sensors were prepared by incorporating the ionophores with o-nitrophenyl octyl ether as plasticizer and potassium tetrakis(4-chlorophenyl) borate as ionic additive into a polyvinyl chloride polymer matrix. These sensors are considered environmentally friendly systems in the analytical research. The linear responses of gemcitabine hydrochloride were in the concentration range of 6.0 × 10−6 to 1.0 × 10−2 mol L−1 and 9.0 × 10−6 to 1.0 × 10−2 mol L−1 and 8.0 × 10−6 to 1.0 × 10−2 mol L−1 for sensors 1, 2, and 3, respectively. Over the pH range of 6–9, fast-Nernst slopes of 52 ± 0.6, 56 ± 0.3, and 55 ± 0.8 mV/decade were found in the same order with correlation regressions of 0.998, 0.999, and 0.998, respectively. The lower limits of detection for the prepared sensors were 2.5 × 10−6, 2.2 × 10−6, and 2.7 × 10−6 mol L−1. The sensors showed high selectivity and sensitivity for gemcitabine. Validation of the sensors was carried out in accordance with the requirements established by the IUPAC, while being inexpensive and easy to use in drug formulation. A statistical analysis of the methods in comparison with the official method showed that there was no significant difference in accuracy or precision between them. It was shown that the new sensors could selectively and accurately find gemcitabine hydrochloride in bulk powder, pharmaceutical formulations, and quality control tests. The ionophore-based sensor shows several advantages over conventional PVC membrane sensor sensors regrading the lower limit of detection, and higher selectivity towards the target ion.
Subject
Chemistry (miscellaneous),Analytical Chemistry,Organic Chemistry,Physical and Theoretical Chemistry,Molecular Medicine,Drug Discovery,Pharmaceutical Science
Reference45 articles.
1. An Anthology of Cancer;Kumar;Innov. Int. J. Med. Pharm. Sci.,2018
2. Wang, E., Sorolla, M.A., Gopal Krishnan, P.D., and Sorolla, A. (2020). From seabed to bedside: A review on promising marine anticancer compounds. Biomolecules, 10.
3. Modified nucleoside triphosphates in bacterial research for in vitro and live-cell applications;Espinasse;RSC Chem. Biol.,2020
4. Metabolism, biochemical actions, and chemical synthesis of anticancer nucleosides, nucleotides, and base analogs;Shelton;Chem. Rev.,2016
5. Fabrication and evaluation of potentiometric sensors of an anticancer drug (Gemcitabine);Saadeh;Eur. J. Chem.,2020
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献