This study investigated the impact of individual and combination of different sources of heating (passive solar heating, electric oil-heater, and solar air heater) in a pilot-scale building containing phase change material (PCM) for a potential reduction in energy consumption while maintaining thermal comfort. Unlike most of the recent simulations and modelling studies, this impact was tested experimentally using two identical control and test huts located at the University of Auckland. The control hut was equipped with standard gypsum boards while the test hut had gypsum boards containing PCM (PureTemp 20, PT20). The study found that combining both active and passive solar heating with a temperature-controlled electric oil heater demonstrated the ability to provide significant energy savings and maintain thermal comfort in the test hut, most notably overnight. The suggested combination was tested over different weather conditions and with different temperature constraints to maintain thermal comfort and achieve energy savings ranging from 33% to 87.5%.