Effect of Stem Design and Positioning on the Leg Axis after Total Hip Arthroplasty: A Secondary Analysis

Author:

Fey Benjamin1,Brenneis Marco1,Stief Felix1ORCID,van Drongelen Stefan2ORCID

Affiliation:

1. Department of Trauma Surgery and Orthopedics, University Hospital Frankfurt, Goethe University Frankfurt, Marienburgstr. 2, 60528 Frankfurt, Germany

2. Dr. Rolf M. Schwiete Research Unit for Osteoarthritis, Department of Trauma Surgery and Orthopedics, University Hospital Frankfurt, Goethe University Frankfurt, Marienburgstr. 2, 60528 Frankfurt, Germany

Abstract

Background/Objectives: Various parameters, like femoral offset and leg length, are associated with good patient outcomes after total hip arthroplasty. In this prospective study, the effects of stem design, its placement in the proximal femur and the resulting femoral offset on the total leg axis were investigated. Methods: The 27 patients included in this study received biplanar radiography (EOS®, EOS Imaging) with 3D reconstruction using sterEOS® both preoperatively and postoperatively. For all leg alignment parameters obtained from the 3D reconstruction and from measurements using mediCAD, the deltas between the postoperative and preoperative values were determined. Patients were divided into those who received a short-stem prosthesis and those who received a straight-stem prosthesis. Results: The change in femoral offset with the implantation of a short-stem prosthesis was significantly greater than that with the implantation of a straight-stem prosthesis (11.4 ± 5.9 vs. 4.6 ± 7.4 mm, p = 0.014). Compared with the straight-stem implantation, short-stem implantation caused a significantly greater increase in the varus orientation of the leg (−1.4 ± 0.9 vs. −0.4 ± 1.4°, p = 0.048). There was no significant difference in the positioning of the short-stem prosthesis compared to the straight-stem prosthesis in the proximal femur (3.6 ± 3.1 vs. 2.6 ± 1.9°, p = 0.317). Conclusions: These findings substantiate the impact of prosthesis design on offset and leg alignment. The implantation of short-stems is more variable and requires precise planning. Intraoperative non-physiological offset changes and varus deviation of the leg axis should be avoided. Trial registration: This study was retrospectively registered with the German Clinical Trials Register (DRKS) under the number DRKS00015053 on the 1 August 2018.

Funder

Deutsche Forschungsgemeinschaft

Publisher

MDPI AG

Reference43 articles.

1. Remodeling of bone tissue around the distal part of Zweymüller stem;Kokoszka;Ortop. Traumatol. Rehabil.,2015

2. Change of offset after implantation of hip alloarthroplasties;Jerosch;Unfallchirurg,2004

3. An international comparison of THA patients, implants, techniques, and survivorship in Sweden, Australia, and the United States;Paxton;Acta Orthop.,2019

4. Implant survival and patient-reported outcome following total hip arthroplasty in patients 30 years or younger: A matched cohort study of 1,008 patients in the Swedish Hip Arthroplasty Register;Mohaddes;Acta Orthop.,2019

5. Personality and comorbidity: Are there “difficult patients” in hip arthroplasty?;Haase;Orthopade,2015

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3