Abstract
This study demonstrates the application of parametric accelerated life testing (ALT) as a procedure to identify design deficiencies and correct them in generating a reliable quantitative (RQ) specification. It includes: (1) a system BX lifetime that X% of a product population fails with a parametric ALT scheme, (2) fatigue design, (3) ALTs with alternations, and (4) judgement as to whether the design(s) secures the desired BX lifetime. A (generalized) life–stress model through the linear transport process and a sample size formulation are suggested. A pneumatic cylinder in a machine tool was used as a case study. The cylinder was failing in a flexible manufacturing system. To reproduce the failure and modify the design, a parametric ALT was performed. At the first ALT, the metal seal made of nickel-iron alloy (36% Ni) partially cracked and chipped and had a crisp metal sound. It was modified by changing the seal from a metal to a polymer (silicone rubber). At the second ALT, the piston seal leaked due to seal hardening and wear. The failure modes of the silicone seal in the laboratory tests were similar to those returned from the field. For the third ALT, the seal material was changed from silicone rubber to (thermoset) polyurethane. There were no concerns during the third ALT and the lifetime of the pneumatic cylinder was shown to have a B1 life of 10 years.