Is Less Always More? A Prospective Two-Centre Study Addressing Clinical Outcomes in Leadless versus Transvenous Single-Chamber Pacemaker Recipients

Author:

Bertelli MicheleORCID,Toniolo SebastianoORCID,Ziacchi MatteoORCID,Gasperetti AlessioORCID,Schiavone MarcoORCID,Arosio RobertoORCID,Capobianco Claudio,Mitacchione GianfrancoORCID,Statuto Giovanni,Angeletti Andrea,Martignani Cristian,Diemberger Igor,Forleo Giovanni BattistaORCID,Biffi MauroORCID

Abstract

(1) Background: Leadless (LL) stimulation is perceived to lower surgical, vascular, and lead-related complications compared to transvenous (TV) pacemakers, yet controlled studies are lacking and real-life experience is non-conclusive. (2) Aim: To prospectively analyse survival and complication rates in leadless versus transvenous VVIR pacemakers. (3) Methods: Prospective analysis of mortality and complications in 344 consecutive VVIR TV and LL pacemaker recipients between June 2015 and May 2021. Indications for VVIR pacing were “slow” AF, atrio-ventricular block in AF or in sinus rhythm in bedridden cognitively impaired patients. LL indication was based on individualised clinical judgement. (4) Results: 72 patients received LL and 272 TV VVIR pacemakers. LL pacemaker indications included ongoing/expected chronic haemodialysis, superior venous access issues, active lifestyle with low pacing percentage expected, frailty causing high bleeding/infectious risk, previous valvular endocarditis, or device infection requiring extraction. No significant difference in the overall acute and long-term complication rate was observed between LL and TV cohorts, with greater mortality occurring in TV due to selection of older patients. (5) Conclusions: Given the low complication rate and life expectancy in this contemporary VVIR cohort, extending LL indications to all VVIR candidates is unlikely to provide clear-cut benefits. Considering the higher costs of LL technology, careful patient selection is mandatory for LL PMs to become advantageous, i.e., in the presence of vascular access issues, high bleeding/infectious risk, and long life expectancy, rendering lead-related issues and repeated surgery relevant in the long-term perspective.

Publisher

MDPI AG

Subject

General Medicine

Reference20 articles.

1. Registro Italiano Pacemaker e Defibrillatori—Bollettino Periodico 2018. Associazione Italiana di Aritmologia e Cardios-timolazione [The Pacemaker and Implantable Cardioverter-Defibrillator Registry of the Italian Association of Arrhythmology and Cardiac Pacing—2018 Annual report];Proclemer;G. Ital. Cardiol.,2020

2. Pacing devices to treat bradycardia: current status and future perspectives

3. Prevention of Arrhythmia Device Infection Trial

4. Early performance of a miniaturized leadless cardiac pacemaker: the Micra Transcatheter Pacing Study

5. A Leadless Intracardiac Transcatheter Pacing System

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3