Assessment of Renal Allograft Stiffness and Viscosity Using 2D SWE PLUS and Vi PLUS Measures—A Pilot Study

Author:

Maralescu Felix-MihaiORCID,Bende Felix,Sporea Ioan,Popescu Alina,Șirli RoxanaORCID,Schiller Adalbert,Petrica LigiaORCID,Moga Tudor VoicuORCID,Mare RuxandraORCID,Grosu Iulia,Bob Flaviu

Abstract

Elastography is a useful noninvasive tool for the assessment of renal transplant recipients. 2D-shear wave elastography (SWE) PLUS and viscosity plane-wave ultrasound (Vi PLUS) have emerged as novel techniques that promise to offer improved renal stiffness and viscosity measures due to improved processing algorithms. Methods: We performed a cross-sectional study of 50 kidney transplanted patients (16 women, 34 men; mean age of 47.5 ± 12.5; mean estimated glomerular filtration rate (eGFR) estimated by Chronic Kidney Disease Epidemiology Collaboration formula: 52.19 ± 22.6 mL/min/1.73 m2; and a mean duration after transplant of 10.09 ± 5 years). For every patient, we obtained five valid measurements of renal stiffness (obtained from five different frames in the cortex of the renal graft), and also tissue viscosity, with a C6-1X convex transducer using the Ultra-Fast™ software available on the Aixplorer Mach 30 ultrasound system (Supersonic Imagine, Aix-en-Provence, France). The median values of elastographic and viscosity measures have been correlated with the patients’ demographic, biological, and clinical parameters. Results: We obtained a cut-off value of renal cortical stiffness of <27.3 kiloPascal(kPa) for detection of eGFR < 60 mL/min/1.73 m2 with 80% sensitivity and 85% specificity (AUC = 0.811, p < 0.0001), a cut-off value of <26.9 kPa for detection of eGFR < 45 mL/min/1.73 m2 with 82.6% sensitivity and 74% specificity (AUC = 0.789, p < 0.0001), and a cut-off value of <23 kPa for detection of eGFR < 30 mL/min/1.73 m2 with 88.8% sensitivity and 75.6% specificity (AUC = 0.852, p < 0.0001). We found a positive correlation coefficient between eGFR and the median measure of renal cortical stiffness (r = 0.5699, p < 0.0001), between eGFR the median measure of viscosity (r = 0.3335, p = 0.0180), between median depth of measures and renal cortical stiffness (r = −0.2795, p = 0.0493), and between median depth of measures and body mass index (BMI) (r = 0.6574, p < 0.0001). Our study showed good intra-operator agreement for both 2D SWE PLUS measures—with an intraclass correlation coefficient (ICC) of 0.9548 and a 95% CI of 0.9315 to 0.9719—and Vi PLUS, with an ICC of 0.8323 and a 95% CI of 0.7457 to 0.8959. The multivariate regression model showed that 2D SWE PLUS values were associated with eGFR, Vi PLUS, and depth of measures. Conclusions: Assessment of renal allograft stiffness and viscosity may prove to be an effective method for identifying patients with chronic allograft injury and could prove to be a low-cost approach to provide additional diagnostic information of kidney transplanted patients.

Publisher

MDPI AG

Subject

General Medicine

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3