Portable Sensor System for Registration, Processing and Mathematical Analysis of PPG Signals

Author:

Georgieva-Tsaneva GalyaORCID,Gospodinova Evgeniya,Gospodinov Mitko,Cheshmedzhiev Krasimir

Abstract

This article introduces an integrated photoplethysmographic (PPG) based cardiovascular monitoring system that consists of an individually portable PPG device for recording photoplethysmographic signals and a software system with a serverless architecture for processing, storing, and analyzing the obtained signals. The portable device uses the optical plethysmography technique for measuring blood volume in blood vessels. The device was tested and validated by a comparative analysis of three photoplethysmographic signals and one Electrocardiographic signal registered simultaneously in the target subject. The comparative analysis of these signals shows insignificant deviations in the obtained results, with the mean squared error between the studied signals being less than 21 ms. This deviation cannot affect the results that were obtained from the analysis of the interval series tested. Based on this result, we assume that the detected signals with the proposed device are realistic. The designed software system processes the registered data, performs preprocessing, determines the pulse rate variability, and performs mathematical analysis of PP intervals. Two groups of subjects were studied: 42 patients with arrhythmia and 40 healthy controls. Mathematical methods for data analysis in time and frequency domain and nonlinear methods (Poincaré plots, Rescaled Range Plot, Detrended Fluctuation Analysis, and MultiFractal Detrended Fluctuation Analysis) are applied. The obtained results are presented in tabular form and some of them in graphical form. The parameters studied in the time and frequency domain, as well as with the nonlinear methods, have statistical significance (p < 0.05) and they can distinguish between the two studied groups. Visual analysis of PP intervals, based on Poincare’s nonlinear method, provides important information on the physiological status of patients, allowing for one to see at a glance the entire PP interval series and quickly detect cardiovascular disorders, if any. The photoplethysmographic data of healthy individuals and patients diagnosed with arrhythmia were recorded, processed, and examined through the system under the guidance of a cardiologist. The results were analyzed and it was concluded that this system could serve to monitor patients with cardiovascular diseases and, when the condition worsens, a signal could be generated and sent to the hospital for undertaking immediate measures to stabilize patient’s health.

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Cited by 12 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3