Comparative Clinical Performances of Tunneled Central Venous Catheters versus Arterio-Venous Accesses in Patients Receiving High-Volume Hemodiafiltration: The Case for High-Flow DualCath, a Tunneled Two-Single-Lumen Silicone Catheter

Author:

Canaud Bernard12ORCID,Leray-Moragues H.3,Chenine Leila4,Morena Marion5ORCID,Miller George6ORCID,Canaud Ludovic7,Cristol Jean Paul35ORCID

Affiliation:

1. School of Medicine, Montpellier University, 34090 Montpellier, France

2. MTX Consulting International, Rue des Carmelites, 34090 Montpellier, France

3. AIDER-Santé, CHARLES, Mion Foundation, 34000 Montpellier, France

4. Nephrology, Intensive Care, Dialysis & Transplantation, Lapeyronie University Hospital, 34090 Montpellier, France

5. PhyMedExp, Department of Biochemistry and Hormonology, INSERM, CNRS, University Hospital Center of Montpellier, University of Montpellier, 34000 Montpellier, France

6. Medical Components, Inc., Clinical Affairs, Harleysville, PA 19438, USA

7. Chest and Vascular Surgery Department, CHU Montpellier, 34000 Montpellier, France

Abstract

Tunneled central venous catheters (CVC) are mainly considered as a rescue vascular access option in dialysis but are still used on approximately one quarter of prevalent patients worldwide even though they are associated with poor performances and higher risks. Study design: in this retrospective single-center study, we aimed to report on the clinical performances achieved with high-flow tunneled CVCs (DualCath or DCath) and compared them with arteriovenous accesses (AVAs, e.g., AV fistula, AV graft, and Thomas Shunt) in a hospital-based dialysis unit. Methods: Sixty-eight stage 5 chronic kidney disease dialysis-dependent patients (CKD5D) receiving high volume hemodiafiltration were followed-up with for 30 months. The study consisted of two phases: baseline cross-sectional and longitudinal follow-ups of key performance indicators. Clinical performances consisting of effective blood flow and blood volume, recirculation, urea and ionic Kt/V, total Kt, ultrafiltration volume, and percent reduction in β2-M were measured monthly as part of quality control in our unit. Results: At baseline, the effective blood flow using a DCath was close to 400 mL/min, similar to an AVA. Recirculation with a DCath (7%, 6–13%) was higher than with an AVA. The diffusive dialysis dose delivered with a DCath (spKt and eKt/V) and convective dialysis dose achieved with a DCath were slightly lower than those achieved with AVAs, but they were still much higher than is recommended by guidelines. The percent reduction in β2-M achieved with a DCath was also 4 to 10% lower than that achieved with an AVA. On longitudinal follow-up, the main clinical performance indicators of DCaths (total Kt and total ultrafiltration volume, L/session) were maintained as very stable over time and close to those achieved with AVAs. Conclusions: As shown in this study, high-flow DualCath tunneled two-single-lumen silicone catheters may be used to deliver high volume hemodiafiltration in a reliable and consistent manner without compromising clinical performance. These results relied on the specific design of the two silicone cannulas and the strict adherence to best catheter practices.

Publisher

MDPI AG

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3