Affiliation:
1. Division of Cardiology, A.O.U. Policlinico “G. Rodolico San Marco”, 95123 Catania, Italy
2. Faculty of Medicine and Surgery, Università degli Studi di Enna “Kore”, 94100 Enna, Italy
Abstract
Background: Concomitant mitral transcatheter edge-to-edge repair (M-TEER) and left atrial appendage closure (LAAC) showed to be a feasible approach to optimize the treatment of patients eligible for both procedures, but mid-term outcomes are unclear. Methods: We retrospectively analyzed consecutive patients undergoing M-TEER and enrolled in the local prospective Getting Reduction of Mitral Insufficiency by Percutaneous Clip Implantation (GRASP) registry. We compared patients undergoing isolated M-TEER (n = 58, 58.5%) with those undergoing concomitant M-TEER and LAAC (n = 41, 41.5%) from January 2018 to December 2022. The primary endpoint was a composite of all-cause death, stroke or systemic embolism, hospitalization for heart failure, and bleeding at 1 year. The co-primary endpoint was procedural success. Results: The primary endpoint was similar between patients undergoing concomitant M-TEER+LAAC or isolated M-TEER (Kaplan Meier (KM) estimates 36.6% vs. 44.8%; plog-rank = 0.75). Procedural success was also similar (92.7% vs. 94.8%; p = 0.69). At 1- year, minor bleeds were lower in patients undergoing concomitant M-TEER and LAAC (KM estimates 0.0% vs. 18.9%; plog-rank < 0.01). Conclusion: In patients with concomitant MR and AF and eligible for M-TEER and LAAC treatment, a combined approach of M-TEER and LAAC was as safe as an M-TEER-alone strategy and associated with lower minor bleeding at 1 year.
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献