External Validation with Accuracy Confounders of VCO2-Derived Predicted Energy Expenditure Compared to Resting Energy Expenditure Measured by Indirect Calorimetry in Mechanically Ventilated Children

Author:

Briassoulis Panagiotis,Ilia StavroulaORCID,Briassouli Efrossini,Briassoulis GeorgeORCID

Abstract

Optimal energy provision, guided by measured resting energy expenditure (REE) and determined by indirect calorimetry (IC), is fundamental in Intensive Care Units (ICU). Because IC availability is limited, methods to predict REE based on carbon dioxide production (VCO2) measurements (REEVCO2) alone have been proposed as a surrogate for REE measured by IC (REEIC). The study aimed at externally and internally validating the accuracy of the REEVCO2 as an alternative to REEIC in mechanically ventilated children. A ventilator’s integrated gas exchange module (E-COVX) was used to prospectively measure REEIC and predict REEVCO2 on 107 mechanically ventilated children during the first 24 h of admission. The accuracy of the REEVCO2 compared to REEIC was assessed through the calculation of bias and precision, paired median differences, linear regression, and ROC analysis. Accuracy within ±10% of the REEIC was deemed acceptable for the REEVCO2 equation. The calculated REEVCO2 based on respiratory quotient (RQ) 0.89 resulted in a mean bias of −72.7 kcal/day (95% limits of agreement −321.7 to 176.3 kcal/day) and a high coefficient of variation (174.7%), while 51.4% of the calculations fell outside the ±10% accuracy rate. REEVCO2 derived from RQ 0.80 or 0.85 did not improve accuracy. Only measured RQ (Beta 0.73, p < 0.001) and no-recorded neuromuscular blocking agents (Beta −0.13, p = 0.044) were independently associated with the REEVCO2−REEIC difference. Among the recorded anthropometric, metabolic, nutrition, or clinical variables, only measured RQ was a strong predictor of REEVCO2 inaccuracy (p < 0.001). Cutoffs of RQ = 0.80 predicted 89% of underestimated REEIC (sensitivity 0.99; specificity 0.89) and RQ = 0.82 predicted 56% of overestimated REEIC (sensitivity of 0.99; specificity 0.56). REEVCO2 cannot be recommended as an alternative to REEIC in mechanically ventilated children, regardless of the metabolic, anthropometric, or clinical status at the time of the evaluation.

Publisher

MDPI AG

Subject

Food Science,Nutrition and Dietetics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3