Verification of Finger Positioning Accuracy of an Affordable Transradial Prosthesis

Author:

Koudelkova Zuzana1,Mizera Ales1ORCID,Karhankova Michaela1,Mach Vaclav1,Stoklasek Pavel1,Krupciak Matej2ORCID,Minarcik Jan3,Jasek Roman1

Affiliation:

1. Faculty of Applied Informatics, Tomas Bata University in Zlin, 760 05 Zlin, Czech Republic

2. Smart View s.r.o., 765 02 Otrokovice, Czech Republic

3. Faculty of Material Science and Technology, Technical University of Ostrava, 708 00 Ostrava, Czech Republic

Abstract

Whether due to unpleasant events, injuries or illnesses, people lose the mobility of their hands. In extreme cases, amputation of the hand or hands can also occur. This paper deals with designing and fabricating an affordable transradial prosthesis using 3D printing and measuring finger positioning accuracy during a long-term test. The prosthesis’ design was inspired by the tested wire construction used in both low-cost commercial and do-it-yourself prostheses. The shape of the partial parts of the prosthesis was adapted for production using 3D printing. A high priority was also placed on using as few electronics as possible, while the used electronics also has to be affordable. Six MG995 servo motors were utilized to provide movement for the fingers, thumbs and wrist, and an Arduino Nano R3 was used to control their function. A control glove was subsequently developed to control the prosthesis, allowing accurate measurement of the angles of the finger’s distal phalanges. Their measured angle served as a reference for matching the angles on the prosthetic hand. To verify the prosthesis’s durability and the finger grip’s accuracy, a long-term test of 100,000 cycles, which repeated the western world’s finger-counting system from 0 to 5, was performed. It was determined that there is only a minor deviation from the initial finger position based on measurements of the accuracy of the finger position before and after the long-term test. Only minimal wear of functional parts after the long-term test was observed. No significant deviations from the desired finger angles were measured.

Funder

Internal Grant Agency of Tomas Bata University

Publisher

MDPI AG

Subject

Industrial and Manufacturing Engineering,Mechanical Engineering,Engineering (miscellaneous)

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3