Computational Analysis of Tube Wall Temperature of Superheater in 1000 MW Ultra-Supercritical Boiler Based on the Inlet Thermal Deviation

Author:

Li Pei1ORCID,Bao Ting2,Guan Jian3,Shi Zifu4,Xie Zengxiao5,Zhou Yonggang4,Zhong Wei1

Affiliation:

1. Institute of Thermal Science and Power Systems, Zhejiang University, Hangzhou 310027, China

2. Zhejiang Provincial Key Laboratory of Energy Conservation & Pollutant Control Technology for Thermal Power, Zhejiang Zheneng Technology Research Institute Co., Ltd., Hangzhou 311121, China

3. Zhejiang Province Energy Group Co., Ltd., Hangzhou 310007, China

4. State Key Laboratory of Clean Energy Utilization, Institute of Thermal Power Engineering, Zhejiang University, Hangzhou 310027, China

5. Zhejiang Zheneng Zhongmei Zhoushan Coal & Electricity Co., Ltd., Zhoushan 316131, China

Abstract

Local over-temperature is one of the main reasons for boiler tube failures (BTF). By accurately monitoring and controlling tube wall temperature, local over-temperature can be avoided. Based on the measured flue gas parameters and numerical simulation, a method of thermal deviation calculation is proposed in this study for the on-line calculation of the tube wall temperature of boiler superheaters. The full-size three-dimensional numerical simulation was presented on the combustion in a pulverized coal-fired boiler of 1000 MW ultra-supercritical (USC) unit. A difference in the thermal deviation of the vertical direction was innovatively introduced into a segmented discrete model, and the thermal deviation condition conforming to reality was introduced into the calculation. An on-line calculation system developed based on the current calculation method was applied in a 1000 MW USC unit. The calculated local high-temperature zone was consistent with the actual over-temperature position and conformed to the law of the allowable metal temperature of the final superheater (FSH) serpentines segment. The comparison results showed that the calculated data by this method were more reflective of tube wall temperature change with boiler loads than the measured data. According to the calculated local over-temperature zone, the immediate warning response can effectively reduce the possibility of over-temperature BTF.

Funder

Zhejiang Province Energy Group Co., Ltd.

Publisher

MDPI AG

Subject

Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous),Building and Construction

Reference29 articles.

1. BP (2021). BP Statistical Review of World Energy 2021, BP Amoco.

2. (2022, October 02). China Electricity Council P A S. Available online: https://cec.org.cn/detail/index.html?3-308855.

3. Causes and mitigation of gas temperature deviation in tangentially fired tower-type boilers;Tan;Appl. Therm. Eng.,2018

4. Thermal load deviation model for superheater and reheater of a utility boiler;Xu;Appl. Therm. Eng.,2000

5. On the failure of steam-side oxide scales in high temperature components of boilers during unsteady thermal processes;Huang;J. Loss Prevent. Proc.,2013

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3