Cochlear Implant Stimulation Parameters Play a Key Role in Reducing Facial Nerve Stimulation

Author:

Gärtner Lutz1ORCID,Backus Bradford C.2ORCID,Le Goff Nicolas2ORCID,Morgenstern Anika1ORCID,Lenarz Thomas13ORCID,Büchner Andreas13ORCID

Affiliation:

1. Department of Otolaryngology, Hannover Medical School, 30625 Hannover, Germany

2. Oticon Medical, 06220 Vallauris, France

3. Cluster of Excellence “Hearing4all”, 30625 Hannover, Germany

Abstract

A percentage (i.e., 5.6%) of Cochlear Implant (CI) users reportedly experience unwanted facial nerve stimulation (FNS). For some, the effort to control this problem results in changing stimulation parameters, thereby reducing their hearing performance. For others, the only viable solution is to deactivate the CI completely. A growing body of evidence in the form of case reports suggests that undesired FNS can be effectively addressed through re-implantation with an Oticon Medical (OM) Neuro-Zti implant. However, the root of this benefit is still unknown: is it due to surgical adjustments, such as varied array geometries and/or positioning, or does it stem from differences in stimulation parameters and/or grounding? The OM device exhibits two distinct features: (1) unique stimulation parameters, including anodic leading pulses and loudness controlled by pulse duration—not current—resulting in lower overall current amplitudes; and (2) unconventional grounding, including both passive (capacitive) discharge, which creates a pseudo-monophasic pulse shape, and a ‘distributed-all-polar’ (DAP) grounding scheme, which is thought to reduce current spread. Unfortunately, case reports alone cannot distinguish between surgical factors and these implant-related ones. In this paper, we present a novel follow-up study of two CI subjects who previously experienced FNS before re-implantation with Neuro-Zti implants. We used the Oticon Medical Research Platform (OMRP) to stimulate a single electrode in each subject in two ways: (1) with traditional monopolar biphasic cathodic-first pulses, and (2) with distinct OM clinical stimulation. We progressively increased the stimulation intensity until FNS occurred or the sound became excessively loud. Non-auditory/FNS sensations were observed with the traditional stimulation but not with the OM clinical one. This provides the first direct evidence demonstrating that stimulation parameters and/or grounding—not surgical factors—play a key role in mitigating FNS.

Publisher

MDPI AG

Subject

General Medicine

Reference25 articles.

1. World Health Organization (2021). World Report on Hearing, World Health Organization.

2. Cochlear implants: A remarkable past and a brilliant future;Wilson;Hear. Res.,2008

3. Niparko, J.K. (2009). Cochlear Implants: Principles & Practices, Lippincott Williams & Wilkins.

4. Factors Influencing Aberrant Facial Nerve Stimulation Following Cochlear Implantation: A Systematic Review and Meta-analysis;Hayden;Otol. Neurotol.,2020

5. Triphasic Pulses in Cochlear Implant Patients with Facial Nerve Stimulation;Braun;Otol. Neurotol.,2019