The Effect of Low-Intensity Pulsed Ultrasound on Bone Regeneration and the Expression of Osterix and Cyclooxygenase-2 during Critical-Size Bone Defect Repair

Author:

Volarić Darian12ORCID,Žauhar Gordana34ORCID,Chen Jie56ORCID,Jerbić Radetić Ana Terezija7,Omrčen Hrvoje8,Raič Antonio9,Pirović Roko9,Cvijanović Peloza Olga7ORCID

Affiliation:

1. Department of Physical Medicine and Rehabilitation, Thalassotherapia Crikvenica—Special Hospital for Medical Rehabilitation, Gajevo Šetalište 21, 51260 Crikvenica, Croatia

2. Doctoral School of Biomedicine and Health, Faculty of Medicine, University of Rijeka, Braće Branchetta 20/1, 51000 Rijeka, Croatia

3. Department of Medical Physics and Biophysics, Faculty of Medicine, University of Rijeka, Braće Branchetta 20/1, 51000 Rijeka, Croatia

4. Faculty of Physics, University of Rijeka, Radmile Matejčić 2, 51000 Rijeka, Croatia

5. Department of Electrical and Computer Engineering, University of Alberta, Edmonton, AB T6G 2V4, Canada

6. Academy for Engineering and Technology, Fudan University, Shanghai 200433, China

7. Department of Anatomy, Faculty of Medicine, University of Rijeka, Braće Branchetta 20/1, 51000 Rijeka, Croatia

8. Department of Clinical Microbiology, Teaching Institute of Public Health of Primorsko-Goranska County, Krešimirova 52a, 51000 Rijeka, Croatia

9. University Integrated Undergraduate and Graduate Study Programme of Medicine, Faculty of Medicine, University of Rijeka, Braće Branchetta 20/1, 51000 Rijeka, Croatia

Abstract

Low-intensity pulsed ultrasound (LIPUS) is a form of ultrasound that utilizes low-intensity pulsed waves. Its effect on bones that heal by intramembranous ossification has not been sufficiently investigated. In this study, we examined LIPUS and the autologous bone, to determine their effect on the healing of the critical-size bone defect (CSBD) of the rat calvaria. The bone samples underwent histological, histomorphometric and immunohistochemical analyses. Both LIPUS and autologous bone promoted osteogenesis, leading to almost complete closure of the bone defect. On day 30, the bone volume was the highest in the autologous bone group (20.35%), followed by the LIPUS group (19.12%), and the lowest value was in the control group (5.11%). The autologous bone group exhibited the highest intensities of COX-2 (167.7 ± 1.1) and Osx (177.1 ± 0.9) expression on day 30. In the LIPUS group, the highest intensity of COX-2 expression was found on day 7 (169.7 ±1.6) and day 15 (92.7 ± 2.2), while the highest Osx expression was on day 7 (131.9 ± 0.9). In conclusion, this study suggests that LIPUS could represent a viable alternative to autologous bone grafts in repairing bone defects that are ossified by intramembranous ossification.

Funder

University of Rijeka

Croatian Science Foundation

Publisher

MDPI AG

Reference48 articles.

1. Therapeutic Applications of Ultrasound;Prog. Biophys. Mol. Biol.,2007

2. Overview of Therapeutic Ultrasound Applications and Safety Considerations;Miller;J. Ultrasound Med.,2012

3. Ultrasound in Contemporary Physiotherapy Practice;Watson;Ultrasonics,2008

4. Comparison of the Acoustic Streaming in Amniotic Fluid and Water in Medical Ultrasonic Beams;Duck;Ultraschall Med.,2006

5. A Review of Low-Intensity Pulsed Ultrasound for Therapeutic Applications;Jiang;IEEE Trans. Biomed. Eng.,2019

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3