Comparison of Flexible Ureteroscope Performance between Reusable and Single-Use Models

Author:

Bragaru Marius12,Multescu Razvan2,Geavlete Petrisor12,Popescu Razvan12ORCID,Geavlete Bogdan12

Affiliation:

1. Department 3—Nephrology, Urology, Immunology and Transplant Immunology, Dermatology, Allergology, “Carol Davila” University of Medicine and Pharmacy, 050474 Bucharest, Romania

2. Department of Urology, “St. John” Emergency Clinical Hospital, 042122 Bucharest, Romania

Abstract

Background: Single-use flexible ureteroscopes for urinary retention have been developed in recent years as an alternative to reusable ureteroscopes in order to eliminate the risk of cross-infections and to solve the primary limitations of traditional reusable flexible ureteroscopes for urinary retention. Methods: In this study, we evaluated and contrasted three of the most recent types of flexible ureteroscopes, including two digital reusable versions (Olympus URF-V and Olympus URF-V2) and one single-use model (Pusen Medi-calUscope UE3022), in both ex vivo and in vivo scenarios. The influence of a variety of instruments on the flow of irrigation and its deflection was investigated ex vivo. In the in vivo investigation, a total of 40 patients were treated with retrograde fURS utilizing URF-V, 20 patients were treated with URF-V2, and 20 patients were treated with single-use fURS. The visibility and maneuverability of each fURS were evaluated by the same urologist during the procedures, and the results were compared. Results: Intraoperatively, we compared the image quality of reusable (URF-V and URF-V2) and single-use fURS USCOPE UE3022 cameras and found that there was no statistically significant difference between the two types of camera. The score for maneuverability was the same (4.2) regardless of whether we used the UscopeUE3022 or the URF-V2, but it was significantly lower (3.8, p = 0.03) when we utilized the URF-V. Irrigation was about the same when utilizing reused scopes, whereas employing a single-use scope was more than fifty percent more effective. Conclusions: The findings of our research indicate that reusable and single-use fURs have visibility and maneuverability characteristics that are at least comparable to one another. The possibilities of the single-use type in terms of irrigation flow and deflection are superior.

Publisher

MDPI AG

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3