A New Method for Defining the Optimal Separation Gap Distance and the Acceptable Structural Pounding Risk on Multistory RC Structures

Author:

Flenga Maria G.1,Favvata Maria J.1ORCID

Affiliation:

1. Civil Engineering Department, University of Patras, 26504 Patras, Greece

Abstract

A proposal to control the structural pounding hazard imposed on multistory reinforced concrete (RC) structures is presented. The main goal is to guarantee the seismic performance of a structure with an acceptable (predefined) risk-targeted parameter without the need to eliminate structural pounding collisions. The key target parameters of this study are the annual probability of exceeding an engineering demand parameter (EDP) capacity level and the separation distance dg between adjacent structures. In this direction, a method that ensures the performance level of critical EDPs due to structural pounding conditions is proposed. The new method involves two decision frameworks that define (a) the optimal separation gap distance dg,minPt at a targeted value of pounding risk (probability per year) Pt (Decision A) and (b) the minimum acceptable structural pounding risk Pmindg,t at a targeted value of separation gap distance dg,t (Decision B). The demand parameters that are incorporated in the proposed method are the peak relative displacement δmax at the top level of colliding without considering pounding conditions and any other critical EDP due to the structural pounding effect. The overall method is based on two distinct acceptable performance objectives, the POs-δmax and the POs-EDP, defined as a function of P vs. dg. For this purpose, a seismic hazard curve compatible with Eurocode’s 8 hazard zone is adopted, and the corresponding demand hazard curves of δmax and EDP are developed. The proposed method is implemented to study the floor-to-floor structural pounding hazard of an eight-story RC frame taking into account different risk-targeted scenarios. The results show that the seismic risk (probability per year) of exceeding the EDP’s capacity level is significantly increased due to structural pounding in comparison to the case of no pounding. Calibration of the structural pounding risk can be obtained by adjusting the separation gap distance dg between the adjacent structures based on the acceptable POs. The POs-δmax is not always an accurate criterion for verifying the capacity level of the critical EDP. Finally, with the proposed method, a variety of POs-EDPs can be used to control the structural pounding risk in terms of dg,minPt and/or Pmindg,t.

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3