Abstract
In order to improve the control performance of a train auxiliary inverter and satisfy the requirements of power quality, harmonics, and unbalanced factor, this paper proposed a design method of a double closed-loop control system based on a complex state variable structure. The method simplifies the design process and takes full account of the effects of coupling and discretization. In the current closed-loop process, this paper analyzed the limitations of the proportional integral (PI) controller and simplified to P controller. In the voltage closed-loop, the paper employed the PI controller plus the resonant controller, designed the parameters of the PI controller. and analyzed the optimal discretization method of the resonant controller under dq axis coupling. Finally, experiments and simulations were conducted to show that the proposed method can achieve the above improvements.
Funder
the Fundamental Research Funds for the Central Universities
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)