Enhancing Tissue Equivalence in 7Li Heavy Ion Therapy with MC Algorithm Optimized Polymer-Based Bioinks

Author:

Ekinci Fatih1ORCID,Acici Koray2ORCID,Asuroglu Tunc3ORCID

Affiliation:

1. Institute of Nuclear Sciences, Ankara University, 06100 Ankara, Turkey

2. Artificial Intelligence and Data Engineering, Ankara University, 06100 Ankara, Turkey

3. Faculty of Medicine and Health Technology, Tampere University, 33014 Tampere, Finland

Abstract

The unique physical properties of heavy ion beams, particularly their distinctive depth–dose distribution and sharp lateral dose reduction profiles, have led to their widespread adoption in tumor therapy worldwide. However, the physical properties of heavy ion beams must be investigated to deliver a sufficient dose to tumors without damaging organs at risk. These studies should be performed on phantoms made of biomaterials that closely mimic human tissue. Polymers can serve as soft tissue substitutes and are suitable materials for building radiological phantoms due to their physical, mechanical, biological, and chemical properties. Extensive research, development, and applications of polymeric biomaterials have been encouraged due to these properties. In this study, we investigated the ionization, recoils, phonon release, collision events, and lateral straggle properties of polymeric biomaterials that closely resemble soft tissue using lithium-ion beams and Monte Carlo Transport of Ions in Matter simulation. The results indicated that the Bragg peak position closest to soft tissue was achieved with a 7.3% difference in polymethylmethacrylate, with an average recoils value of 10.5%. Additionally, average values of 33% were observed in collision events and 22.6% in lateral straggle. A significant contribution of this study to the existing literature lies in the exploration of secondary interactions alongside the assessment of linear energy transfer induced by the 7Li beam used for treatment. Furthermore, we analyzed the tissue-equivalent properties of polymer biomaterials using heavy ion beams, taking into account phonon release resulting from ionization, recoils, lateral straggle, and all other interactions. This approach allows for the evaluation of the most suitable polymeric biomaterials for heavy ion therapy while considering the full range of interactions involved.

Publisher

MDPI AG

Subject

Biomedical Engineering,Biomaterials

Reference46 articles.

1. Simulation based analysis of 4He, 7Li, 8Be and 10B ions for heavy ion therapy;Ekinci;Int. J. Radiat. Res.,2023

2. Secondary radiation measurements for particle therapy applications: Prompt photons produced by 4He.12C and 16O ion beams in a PMMA target;Mattei;Phys. Med.,2017

3. Carbon-ion radiotherapy for inoperable head and neck bone and soft-tissue sarcoma: Prospective observational study;Musha;Antıcancer Res.,2022

4. Characterizing the Potency and Impact of Carbon Ion Therapy in a Primary Mouse Model of Soft Tissue Sarcoma Relative Potency of Carbon Ions in Primary Mouse Sarcomas;Brownstein;Mol. Cancer Ther.,2018

5. Horst, F., Schardt, D., Iwase, H., Schuy, C., Durante, M., and Weber, U. (2021). Physical characterization of 3He ion beams for radiotherapy and comparison with 4He. Phys. Med. Biol., 66.