Abstract
In order to increase the power rating of electric vehicles, insulated gate bipolar translator (IGBT) modules with multiple power terminals are usually adopted. The transient current sharing of the same polarity power terminals is related to the stray inductance in the branches of the bus-bar. Based on the laminated bus-bar of a three-phase inverter in the electric vehicles that consists of asymmetrical parallel branches, this paper investigates the transient current imbalance sharing caused by the asymmetrical stray inductance in the parallel branches of the bus-bar from the view of energy storing and releasing of stray inductance for the first time. Besides, the partial self-inductance and mutual-inductance model of the parallel branches is set up. Finally, a high-precision partial stray inductance measurement method is proposed, and the accuracy of the partial stray inductance model for asymmetrical parallel branches is verified by experimental tests.
Funder
National Key Research and Development Program of China
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)
Cited by
14 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献