Photobleaching Effect on the Sensitivity Calibration at 638 nm of a Phosphorus-Doped Single-Mode Optical Fiber Dosimeter

Author:

Fricano Fiammetta1ORCID,Morana Adriana1ORCID,Roche Martin123,Facchini Alberto14,Mélin Gilles3,Clément Florence2,Balcon Nicolas2,Mekki Julien2,Marin Emmanuel1ORCID,Ouerdane Youcef1ORCID,Boukenter Aziz1ORCID,Robin Thierry3,Girard Sylvain15ORCID

Affiliation:

1. Laboratory Hubert Curien, Université Jean Monnet, 42000 Saint-Etienne, France

2. CNES, 31400 Toulouse, France

3. Exail, 22300 Lannion, France

4. Department of Electrical and Information Engineering, Politecnico di Bari, 70125 Bari, Italy

5. Institut Universitaire de France (IUF), Ministère de l’Enseignement Supérieur et de la Recherche, 1 rue Descartes, 75005 Paris, France

Abstract

We investigated the influence of the photobleaching (PB) effect on the dosimetry performances of a phosphosilicate single-mode optical fiber (core diameter of 6.6 µm) operated at 638 nm, within the framework of the LUMINA project. Different irradiation tests were performed under ~40 keV mean energy fluence X-rays at a 530 µ Gy(SiO2)/s dose rate to measure in situ the radiation-induced attenuation (RIA) growth and decay kinetics while injecting a 638 nm laser diode source with powers varying from 500 nW to 1 mW. For injected continuous power values under 1 µW, we did not measure any relevant influence of the photobleaching effect on the fiber radiation sensitivity coefficient of ~140 dB km−1 Gy−1 up to ~30 Gy. Above 1 µW, the fiber radiation sensitivity is significantly reduced due to the PB associated with the signal and can decrease to ~80 dB km−1 Gy−1 at 1 mW, strongly affecting the capability of this fiber to serve as a dosimeter-sensitive element. Higher power values up to 50 µW can still be used by properly choosing a pulsed regime with periodic injection cycles to reduce the PB efficiency and maintain the dosimetry properties. Basing on the acquired data, a simple model of the photobleaching effect on a coil of the investigated fiber is proposed in order to estimate its sensitivity coefficient evolution as a function of the cumulated dose and its fiber length when injecting a certain laser power. Additional studies need to investigate the influence of the temperature and the dose rate on the PB effects since these parameters were fixed during all the reported acquisitions.

Publisher

MDPI AG

Reference36 articles.

1. Cancer Risk from Exposure to Galactic Cosmic Rays: Implications for Space Exploration by Human Beings;Cucinotta;Lancet Oncol.,2006

2. Barth, J.L., LaBel, K.A., and Poivey, C. (2004, January 17–20). Radiation Assurance for the Space Environment. Proceedings of the 2004 International Conference on Integrated Circuit Design and Technology (IEEE Cat. No.04EX866), Austin, TX, USA.

3. Eckart, P. (1996). Future Life Support in Space. Spaceflight Life Support and Biospherics, Springer.

4. Space Radiation Cancer Risks and Uncertainties for Mars Missions;Cucinotta;Radiat. Res.,2001

5. Radiation Protection Guidance for Activities in Low-Earth Orbit;Townsend;Adv. Space Res.,2002