IOL Power Calculation in an Unusual Long Fellow Eye: A Case Report

Author:

Camellin Umberto1ORCID,Franchina Francesco1,Meduri Alessandro1,Aragona Pasquale1ORCID

Affiliation:

1. Department of Biomedical and Dental Sciences and Morphofunctional Imaging, University of Messina, 98125 Messina, Italy

Abstract

Background: Intra-Ocular Lens (IOL) power calculation in long eyes remains challenging despite the availability of new formulas and biometers. This case report shows that optimization of the A-constant in the first eye can reduce postoperative refractive error in the second eye, even in the case of an IOL with negative power. This report aimed to describe a case in which this method was used to calculate IOL power to reduce postoperative refractive error in a long fellow eye. As far as we know, this is the first paper reporting the use of the optimized constant in the first eye to reduce postoperative error in the second eye in the case of a negative IOL. Case presentation: A highly myopic patient with nuclear cataracts underwent phacoemulsification cataract surgery (PCS) in both eyes. The axial length (AL) was 39.42 mm in the right eye and 37.45 mm in the left eye. All biometric data were obtained via low-coherence reflectometry using an OA-2000 biometer (Tomey, Nagoya, Japan). First, an IOL power calculation using the Barrett II formula and PCS was performed in the shorter eye. To evaluate the postoperative refractive error, the optimized A-constant in the left eye was estimated using the Camellin-Calossi formula. The new A-constant was then used for the right eye IOL power calculation using the same formula. The prediction error (PE) in the left eye was −0.23 D with the Barrett II formula. The optimized A-constant method using the Camellin-Calossi formula in the fellow eye gave −0.28 D of PE. Conclusions: The A-constant optimization for very long eyes, using data from the first operated eye, may be useful to reduce refractive prediction error in the second eye in very long eyes, as well as in the case of IOL power with negative values.

Publisher

MDPI AG

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3